马来西亚沐若水电站计算机监控系统是在满足沐若水电站EPC合同和遵循我国相关规程规范的基础上,针对电站监控范围广、对象多等特点,兼顾当地电网及用户要求,为保证电站安全运行而设计的。主要介绍了水电站计算机监控系统的总体设计原则、系统结构、系统设备配置及主要特点。系统实现了对水轮发电机组、主变压器、275 kV开关站等设备的实时监控及洪水报警功能。该设计方案可以为今后类似电站项目的监控系统设计提供参考。
The computer monitoring and controlling system for Murum Hydropower Station in Malaysia is designed under the conditions of meeting EPC contract of Murum Hydropower Station, following the correlative specifications and procedures of Chi- na, and according to the characteristics of large monitoring scope and multiple monitoring objects as well as the demands of elec- tricity network and users. We mainly present the general principles, structure, configuration and main characteristics of the sys- tem. The monitoring system can realize real time monitoring on turbine units, main transformer and 275 kV switch yard and flood Marm function.
出处
《人民长江》
北大核心
2013年第8期83-85,共3页
Yangtze River
关键词
计算机监控系统
系统结构
洪流报警
沐若水电站
computer monitoring system
system structure
flood alarm
Murum Hydropower Station