期刊文献+

1000MW机组汽动给水泵系统优化设计分析 被引量:5

Analysis on Design Optimization of Steam Turbine Driven Feed Pump for 1000MW Units
下载PDF
导出
摘要 结合目前大型超超临界火力发电机组锅炉汽动给水泵的设备制造和运行经验,对1台100%汽动给水泵和2台50%汽动给水泵的两种给水泵组系统设计进行技术经济分析。结果表明:1台100%汽动给水泵效率高,能降低机组煤耗0.3g/(kW.h)。 In combination with current equipment manufacturing and operation experience in steam turbine driven feed pump for boilers of large-scale ultra supercritical power unit, technical and economical analysis were conducted to the design schemes respectively with one 100% steam turbine driven feed pump and two 50% steam turbine driven feed pumps. Results show that the system efficiency with one 100% steam turbine driven feed pump is higher and the coal consumption of the unit can be reduced by 0. 3 g/(kW, h).
作者 李伯奎
出处 《发电设备》 2013年第3期165-167,共3页 Power Equipment
关键词 火电厂 给水泵 汽轮机 效率 thermal power plant feed pump steam turbine efficiency
  • 相关文献

参考文献2

  • 1贾世胜.矿井轨道运输监控系统的研究与设计[D].山东:山东科技大学,2007.
  • 2郑体宽.热力发电厂[M].北京:中国电力出版社,2003.

共引文献28

同被引文献23

引证文献5

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...