摘要 为了满足区域性稳控系统在联调过程中站站之间、厂站之间视音频的通信需求,提出了利用稳控系统的数据传输信道的剩余闲置带宽传送现场语音及图像的方法,分析了稳控系统的通信报文与视音频数据包的不同特点,给出了混编两类不同数据类型的编码算法及无失真实时分离识别算法。利用优先级划定法解决了稳控系统对数据实时性要求与语音图像数据流量大的矛盾,并建立了一对一及一对多的实际稳控系统模型进行试验验证。试验结果表明,在保证稳控系统的运行安全可靠的同时,语音图像传送流畅清晰,有效利用了稳控系统信道的闲置带宽,提高了通信通道的利用率。研究成果在广东220kV端州变及1120MW云浮电厂的稳控系统中安装使用,有效提高了稳控系统联调时的效率及结果准确性,并在厂站的日常运维监控中提供了极大的方便性。 In order to meet the communication requirement that emerges from the joint debugging process between station and station or plant and station for regional stability control system, this paper proposes a method for transmitting video-audio data on-spot via the idle bandwidth of the data transmission channel of regional stability control systems and analyzes the differences between communications of regional stability control systems and video-audio data packets. What's more, it gives a coding algorithm which mix coded two different data types and a distortionless real-time separation recognition algorithm. At last, it uses priority designated method to solve the contradiction between data timeliness of the stability control systems and excessive video-audio data traffic, in addition, establishes an actual stability control system model (one-to-one or one-to-many) for experimental verification. The test results show that stability control system works safely and reliably, the image transmission is smooth and clear, and using the method mentioned above has significantly improved the utilization of the communication channel. The research achievement has been used in the stability control systems of 220 kV Duanzhou transfolxner substation and 1120 MW Yunfu power plant, which effectively improves the efficiency and the accuracy of the stability control systems joint debugging, and provides a great convenience in the day-to-day operation and maintenance monitoring.
出处 《电力系统保护与控制》 EI CSCD 北大核心 2013年第10期80-85,共6页 Power System Protection and Control
关键词 稳控系统 联调通信 2 M通道 视音频 码流混编 无损分离 regional stability control systems joint debugging communications 2 M channel video and audio coding mix coded separation recognition
  • 相关文献

参考文献14

二级参考文献53

共引文献158

同被引文献35

  • 1顾洁,陈章潮,张焰,任年荣,张式训.城市电网变压器负载率取值研究[J].电力系统及其自动化学报,1995,7(4):26-32. 被引量:9
  • 2傅旭,王锡凡.一种新的节点静态电压稳定指标及切负荷算法[J].电网技术,2006,30(10):8-12. 被引量:34
  • 3余文杰,方勇杰.一种基于SMARTDevice的低压切负荷算法[J].电力系统自动化,2006,30(21):57-60. 被引量:12
  • 4ANGUERA X, WOOTERS C, PESKIN B, et al. Robust speaker segmentation for meetings: The ICSI- SRI spring 2005 diarization system [C]//Machine Learning for Multimodal Interaction, 2006: 402-414.
  • 5HUNG H, HUANG Yan, FRIEDLAND G, et al. Estimating dominance in multi-party meetings using speaker diarization[J]. IEEE Transactions on Audio, Speech and Language Processing, 2011, 19(4): 847- 860.
  • 6KINNUNEN T, KAPROV E, FRANTI P. Realtime speaker identification and verification[J]. IEEE Transactions on Audio, Speech and Language Processing, 2006, 14(1): 277-288.
  • 7APSINGEKAR V R, DE LEON P L. Speaker model clustering for efficient speaker identification in large population applications [J]. IEEE Transactions on Audio, Speech, and Language Processing, 2009, 17(4) : 848-853.
  • 8DL 755-2001.电力系统安全稳定导则[S],2001.
  • 9Otomega, Bogdan,Glavic, Mevludin,Van Cutsem, Thierry.Distributed undervoltage load shedding. IEEE Transactions on Power Systems . 2007
  • 10F.M. Echavarren,E. Lobato,L. Rouco.??A corrective load shedding scheme to mitigate voltage collapse(J)International Journal of Electrical Power and Energy Systems . 2005 (1)

引证文献5

二级引证文献18

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部