以实际工程为研究对象,分别建立垂直U型地埋管管群的二维和三维非稳态传热模型.以Fluent作为计算工具,进行系统运行15年的换热耦合计算,得到不同换热条件下的土壤温度变化曲线.以三维模型数值计算结果为对比条件,以拟合优度为参照参数,对二维传热模型的应用条件进行了分析.
Choice of a heat transfer model for buried tube-group heat exchangers (GHEs) is the key to accurate calculation of the heat exchange of GHEs in ground-coupled heat pump (GCHP) system. Based on practical projects, the 2D and 3D unsteady heat transfer models of vertical U-tube GHEs are constructed. With Fluent as a computational tool, the heat coupled calculations for a period of 15 years are carried out and soil temperature variation curves are obtained. By taking the 3D model numerical results as benchmark and goodness-of-fit as reference parameter, application conditions for the 2D model are analyzed.
出处
《中国科学院研究生院学报》
CAS
CSCD
北大核心
2013年第3期311-316,321,共7页
Journal of the Graduate School of the Chinese Academy of Sciences
基金
中央高校基本科研业务费(CDJZR11210001)资助
关键词
地埋管地源热泵
管群换热器
三维计算模型
二维计算模型
ground-coupled heat pump
pipe-group heat exchangers
3D calculation model
2D calculation model