摘要
印度古尔冈地处新德里西南30 km,环境条件恶劣,夏季最高温度可达47℃。高温环境对地铁车辆空调系统要求较高,经研究,采用并联式压缩机的大功率空调机组并配合合理的风道系统可有效解决高温环境工况。介绍了印度古尔冈地铁车辆空调系统的设计方案,详细介绍了空调机组选型及与风道的匹配性,并通过试验验证了设计的合理性。
Gurgaon locate at 30 kilometers southwest of New Delhi with badly climate, where the temperature should reach 47~C at summer. The climate is strict to the air conditioning system of vehicle. By research, adopting parallel connection compressor and rea- sonable air duct system can solve the problem effective. The article describes the air - conditioning system of Gurgaon subway vehicle, detailed describes the selection of air conditioning unit and the cooperation with air duct. And then verify the design by test.
出处
《技术与市场》
2013年第5期85-86,共2页
Technology and Market
关键词
古尔冈地铁
并联压缩机
空调系统
Gurgaon subway vehicle
parallel connection compressor
air conditioning system