计量站外输管线频繁腐蚀穿孔失效分析 被引量:1

Analysis of the Frequent Perforation Corrosion Failures of the Delivery Line of Metering Station
下载PDF
导出
摘要 通过对Y11-2计量站500m新投外输管线失效的宏观腐蚀形貌、材料化学成分和金相组织、输送液组分和腐蚀速率分析,认为该管线材料合格,输送液体腐蚀性较强,该管线未能形成连续的腐蚀产物保护膜是造成频繁穿孔的原因。 Based on the analyses of the macro corrosion morphology, chemieal composition and metallographie structure of the materi- al, transmission fluid e, omponents and corrosion rate of the eorrosiun failure in the new delivery line of Metering Station Y I 1-2, the paper holds that the material of the line is eligible, and the frequent corrosion failures are primarily caused by the failure of the for- marion of enntinuous protective film against corrosion products due to the strong corrosiveness of the transmission fluid.
出处 《石油工业技术监督》 2013年第5期12-14,共3页 Technology Supervision in Petroleum Industry
关键词 计量站 外输管线 穿孔 金相组织 矿化度 腐蚀速率 metering station delivery line perforation metallographic structure mineralization degree corrosion rate