摘要 目的验证自制金属胫骨截骨髓外定位辅助器对提高全膝关节置换术(TKA)后力线准确率的影响及临床疗效。方法自2010年6月至2011年11月对膝关节晚期病变患者72例81膝进行TKA,术前在透视下应用自制金属胫骨截骨髓外定位辅助器确定胫骨机械轴并标记于胫前皮肤。术中按标识线引导髓外定位导向器进行胫骨截骨,常规完成手术。术后测量假体力线偏差角计算准确率,6个月时应用美国膝关节协会评分(KSS)评分标准进行疗效评价。结果术后胫骨假体力线准确率达97.2%。1年内未发现假体松动、感染等并发症。6个月时应用KSS评分标准进行评价,优良率达95.8%。结论自制金属胫骨截骨髓外定位辅助器可以提高TKA术后力线准确率,临床疗效可靠。
出处 《中华损伤与修复杂志(电子版)》 CAS 2013年第1期52-53,共2页 Chinese Journal of Injury Repair and Wound Healing(Electronic Edition)
  • 相关文献

参考文献8

  • 1Longstaff LM, Sloan K, Stamp N, et al. Good alignment after total knee arthroplasty leads to faster rehabilitation and better function [J]. J Arthroplasty, 2009, 24(4) : 570-578.
  • 2尚延春,陈海龙,王战朝.引起全膝表面假体置换手术下肢力线不好的几个原因[J].中医正骨,2007,19(8):45-46. 被引量:7
  • 3Jeffery RS, Morris RW, Denham RA. Coronal alignment after total knee replacement [J]. J Bone Joint Surg Br, 1991, 73(5): 709 -714.
  • 4Dennis DA, Channer M, Susman MH, ct al. Intramedullary versus extramedullary tibial alignment systems in total knee arthroplasty [J]. J Arthroplasty, 1993, 8(1) : 43-47.
  • 5Engh GA, Petersen TL. Comparative experience with intramedullary and extramedullary alignment in total knee arthroplasty [ J ]. J Arthroplasty, 1990, 5 ( 1 ) : 1-8.
  • 6Teter KE, Bregman D, Colwell CW Jr. Accuracy of intramedullary versus extramedullary tibial alignment cutting systems in total kneearthroplasty [J]. Clin Orthop Relat Res, 1995(321) : 106-110.
  • 7许伟华,杨述华,陈东,叶树楠,冯勇,张波,刘先哲.计算机导航辅助下与传统全膝关节置换术后下肢力线和假体位置的比较[J].中华创伤骨科杂志,2011,13(12):1130-1134. 被引量:8
  • 8李国梁,韩广普,邓文涛,许雪梅,张金秀,袁福禄,褚俊链,房庆鹏.全膝关节置换术中自制金属胫骨截骨髓外定位辅助器的应用[J].中华损伤与修复杂志(电子版),2013,8(1):52-53. 被引量:7

二级参考文献42

  • 1尚延春,陈海龙,王战朝.引起全膝表面假体置换手术下肢力线不好的几个原因[J].中医正骨,2007,19(8):45-46. 被引量:7
  • 2Bargren JH, Blaha JD, Freeman MA. Alignment in total knee arthroplasty:correlated biomechanical and clinical observations.Clin Orthop Relat Res,1983(173):178-183.
  • 3Hvid I,Nielsen S.Total condylar knee arthroplasty:prosthetic component positioning and radiolucent lines.Acta Orthop Scand,1984,55:160-165.
  • 4Jeffery RS,Morris RW,Denham RA.Coronal alignment after total knee replacement.J Bone Joint Surg Br,1991,73:709-714.
  • 5Lotke PA,Ecker ML.Influence of positioning of prosthesis in total knee replacement.J Bone Joint Surg Am,1977,59:77-79.
  • 6Rand JA,Coventry MB.Ten-year evaluation of geometric total knee arthroplasty.Clin Orthop Relat Res,1988(232):168-173.
  • 7Ritter MA,Faris PM,Keating EM,et al.Postoperative alignment of total knee replacement:its effect on survival.Clin Orthop Relat Res,1994(299):153-156.
  • 8Petersen TL,Engh GA.Radiographic assessment of knee alignment after total knee arthroplasty.J Arthroplasty,1988,3:67-72.
  • 9Mahaluxmivala J,Bankes MJ,Nicolai P,et al.The effect of surgeon experience on component positioning in 673 Press Fit Condylar posterior cruciate-sacrificing total knee arthroplasties. J Arthroplasty,2001,16:635-640.
  • 10Mielke RK,Clemens U,Jens JH,et al.Navigation in knee endoprosthesis implantation- preliminary experiences and prospective comparative study with conventional implantation technique.Z Orthop Ihre Grenzgeb,2001,139:109-116.

共引文献17

同被引文献66

引证文献7

二级引证文献46

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部