Usefulness of lumen area parameters determined by intravascular ultrasound to predict functional significance of intermediate coronary artery stenosis 被引量:3

Usefulness of lumen area parameters determined by intravascular ultrasound to predict functional significance of intermediate coronary artery stenosis
原文传递
导出
摘要 Background Coronary artery disease is the leading cause of death in China. Percutaneous coronary intervention is a recent milestone technology for treatment coronary artery disease. However, clinical decision making for patients with intermediate coronary stenosis is still controversial. We designed this study to assess the optimal intravascular ultrasound (IVUS) criteria for predicting functional significance of intermediate coronary lesions. Methods We enrolled 141 patients with 165 intermediate coronary lesions located in vessels with a diameter 〉2.50 mm. IVUS of intermediate coronary lesions were performed before intervention. Pressure-derived fractional flow reserve (FFR) was measured at maximal hyperemia induced by adenosine infusion. An FFR 〈0.80 was considered as abnormal functional significance. Results For the overall 165 lesions, the mean FFR value was 0.84±0.09. The diameter of the stenosis by visual estimation on angiogram was (59.63±11.29)%. Minimum lumen diameter (MLD), minimum lumen area (MLA) and plaque burden (PB) were (2.00±0.36) mm, (3.88±1.34) mm2, (67.28±9.89)% respectively by IVUS measurements. An FFR 〈0.80 was seen in 43 lesions (30.5%). There was a moderate correlation between IVUS parameters and FFR, including MLD (r=0.372, P 〈0.001 ), MLA (r=0.442, P 〈0.001 ) and PB (t=-0.172, P 〈0.05). MLA was a predictor for FFR as a continuous variable independent of possible confounding variables (P 〈0.05), and MLA and PB, were predictors for FFR 〈0.80 as binary variables (P 〈0.05). The best cutoff value of MLA to predict FFR 〈0.80 was 〈3.15 mm2, with a 73.6% diagnostic accuracy; sensitivity 71.4%, specificity 67.0%, AUC=0.709, and P 〈0.001. The cutoff value of the PB to predict FFR 〈0.80 was 65.45%; sensitivity 82.6%, specificity 41.2%, AUC=0.644, and P 〈0.01. If both MLA and PB were taken into account, the negative predictive value and the positive predictive value were 88.7% and 64.8% respectively. Conclusions Anatomic measurements of intermediate coronary lesions obtained by IVUS showed a moderate correlation to FFR values. IVUS-derived MLA 〉3.15 mm2 may be useful to exclude FFR 〈0.80, but poor specificity limits its applicability for physiological assessment of lesions 〈3.15 mm2. MLA was one of many factors affecting coronary flow hemodynamics. Both MLA and PB should be taken into account when determining functional ischemia. Background Coronary artery disease is the leading cause of death in China. Percutaneous coronary intervention is a recent milestone technology for treatment coronary artery disease. However, clinical decision making for patients with intermediate coronary stenosis is still controversial. We designed this study to assess the optimal intravascular ultrasound (IVUS) criteria for predicting functional significance of intermediate coronary lesions. Methods We enrolled 141 patients with 165 intermediate coronary lesions located in vessels with a diameter 〉2.50 mm. IVUS of intermediate coronary lesions were performed before intervention. Pressure-derived fractional flow reserve (FFR) was measured at maximal hyperemia induced by adenosine infusion. An FFR 〈0.80 was considered as abnormal functional significance. Results For the overall 165 lesions, the mean FFR value was 0.84±0.09. The diameter of the stenosis by visual estimation on angiogram was (59.63±11.29)%. Minimum lumen diameter (MLD), minimum lumen area (MLA) and plaque burden (PB) were (2.00±0.36) mm, (3.88±1.34) mm2, (67.28±9.89)% respectively by IVUS measurements. An FFR 〈0.80 was seen in 43 lesions (30.5%). There was a moderate correlation between IVUS parameters and FFR, including MLD (r=0.372, P 〈0.001 ), MLA (r=0.442, P 〈0.001 ) and PB (t=-0.172, P 〈0.05). MLA was a predictor for FFR as a continuous variable independent of possible confounding variables (P 〈0.05), and MLA and PB, were predictors for FFR 〈0.80 as binary variables (P 〈0.05). The best cutoff value of MLA to predict FFR 〈0.80 was 〈3.15 mm2, with a 73.6% diagnostic accuracy; sensitivity 71.4%, specificity 67.0%, AUC=0.709, and P 〈0.001. The cutoff value of the PB to predict FFR 〈0.80 was 65.45%; sensitivity 82.6%, specificity 41.2%, AUC=0.644, and P 〈0.01. If both MLA and PB were taken into account, the negative predictive value and the positive predictive value were 88.7% and 64.8% respectively. Conclusions Anatomic measurements of intermediate coronary lesions obtained by IVUS showed a moderate correlation to FFR values. IVUS-derived MLA 〉3.15 mm2 may be useful to exclude FFR 〈0.80, but poor specificity limits its applicability for physiological assessment of lesions 〈3.15 mm2. MLA was one of many factors affecting coronary flow hemodynamics. Both MLA and PB should be taken into account when determining functional ischemia.
出处 《Chinese Medical Journal》 SCIE CAS CSCD 2013年第9期1606-1611,共6页 中华医学杂志(英文版)
基金 This work was supported by grants from the Capital Characteristic Clinical Application Research from Beijing Science and Technology Committee (No. Z111107058811003), the National Natural Science Foundation of China (No. 81070260, No. 81200167), the Beijing Natural Science Foundation (No. 7102099) and the Young Core Fund from Peking University Third Hospital.
关键词 fractional flow reserve intravascular ultrasound intermediate coronary lesion minimal lumen area fractional flow reserve intravascular ultrasound intermediate coronary lesion minimal lumen area
  • 相关文献

参考文献21

  • 1Hu SS, Kong LZ, Gao RL. Report of Chinese cardiovascular disease in 2010. Beijing: China Encyclopedia Publishing House; 2011: 75-80.
  • 2Abizaid A, Mintz GS, Pichard AD, Kent KM, Satler LF, Walsh CL, et al. Clinical, intravascular ultrasound, and quantitative angiographic determinants of the coronary flow reserve before and after percutaneous transluminal coronary angioplasty. Am J Cardiol 1998; 82: 423-428.
  • 3Pijls NH, Van Gelder B, Van der Voort P, Peels K, Bracke FA, Bonnier HJ, et al. Fractional flow reserve. A useful index to evaluate the influence of an epicardial coronary stenosis on myocardial blood flow. Circulation 1995; 92: 3183-3193.
  • 4Pijls NH, De Bruyne B, Peels K, Van Der Voort PH, Bonnier HJ, Bartunek JKJJ, et al. Measurement of fractional flow reserve to assess the functional severity of coronary-artery stenoses. N Engl J Med 1996; 334: 1703-1708.
  • 5Baumgart D, Haude M, Goerge G, Ge J, Vetter S, Dagres N, et al. Improved assessment of coronary stenosis severity using the relative flow velocity reserve. Circulation 1998; 98: 40-46.
  • 6De Bruyne B, Pijls NH, Bartunek J, Kulecki K, Bech JW, De Winter H, et al. Fractional flow reserve in patients with prior myocardial infarction. Circulation 2001; 104: 157-162.
  • 7Puri R, Kapadia SR, Nicholls SJ, Harvey JE, Kataoka Y, Tuzcu M. Optimizing outcomes during left main percutaneous coronary intervention with intravascular ultrasound and fractional flow reserve. J Am Coli Cardiol Intv 2012; 5: 697-707.
  • 8Berger A, Botman KJ, MacCarthy PA, Wijns W, Bartunek J, Heyndrickx GR, et al. Long-term clinical outcome after fractional flow reserve-guided percutaneous coronary intervention in patients with multi vessel disease. J Am Coli Cardiol 2005; 46: 438-442.
  • 9Wongpraparut N, Yalamanchili V, Pasnoori V, Satran A, Chandra M, Masden R, et al. Thirty-month outcome after fractional flow reserve-guided versus conventional multi vessel percutaneous coronary intervention. Am J Cardiol 2005; 96: 877-884.
  • 10Bech GJ, De Bruyne B, Pijls NH, de Muinck ED, Hoomtje lC, Escaned J, et al. Fractional flow reserve to determine the appropriateness of angioplasty in moderate coronary stenosis: a randomized trial. Circulation 2001; 103: 2928-2934.

同被引文献3

引证文献3

二级引证文献12

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部