期刊文献+

双源CT心肌负荷灌注检查的护理

The Nursing of Dynamic Myocardial CT Perfusion Imaging with Dual-source CT
下载PDF
导出
摘要 目的探讨双源CT心肌负荷灌注检查中相关的护理因素。方法对19例临床怀疑心肌缺血或心肌梗塞的患者行双源CT心肌负荷灌注检查的患者在检查前、检查过程中及检查后采用有效的护理流程进行严格的护理。结果 19例患者中的图像均能满足影像学评价,未出现不良反应。结论严格和有效的护理流程是双源CT心肌负荷灌注检查成功和提高图像质量的重要保证。 Objective To investigate the role of related nursing of Stress dynamic myocardial CT perfusion imaging with dual-source CT. Methods In this study. 19 patients with suspected Myocardial ischemia or infarction were enrolled. All patients underwent Stress dynamic myocardial CT perfusion scan with dual-source CT. The strict nursing operation was performed in all patients before exam, during exam, and after exam. Results All the patients had obtained successful dynamic myocardial CT perfusion imaging without adverse effect. Conclusion The strict and effective nursing is essential for the success and image quality of dynamic myocardial CT perfusion imaging with dual-source CT.
出处 《罕少疾病杂志》 2013年第2期22-25,64,共5页 Journal of Rare and Uncommon Diseases
关键词 护理 心肌灌注 体层摄影术 x线计算机 Nursing Myocardial CT perfusion Tomography, X-ray computed
  • 相关文献

参考文献19

  • 1Hendel RC, Berman DS, Di Carli MF, et al. ACCF/ASNC/ACR/ AHA/ASE/SCCT/SCMR/SNM 2009 appropriate use criteria for cardiac radionuclide imaging: a report of the American College of Cardiology Foundation Appropriate Use Criteria Task Force, the American Society of Nuclear Cardiology, the American College of Radiology, the American Heart Association, the American Society of Echocardiography, the Society of Cardiovascular Computed Tomography, the Society for Cardiovascular Magnetic Resonance, and the Society of Nuclear Medicine: endorsed by the American College of Emergency Physicians[J]. Circulation, 2009, 119:e561-e587.
  • 2Hendel RC, Patel MR, Kramer CM, et al. ACCF/ACR/SCCT/ SCMR/ASSC/NASCI/SCA:/SIR 2006 appropriateness criteria for cardiac computed tomography and cardiac magnetic resonance imaging: a report of the American College of Cardiology Foundation Quality Strategic Directions Corr:nittee Appropriateness CriteriaWorking group, American College of Radiology, Society of Cardiovascular Computed Tomography, Society for Cardiovascular Magnetic Resonance, American Society of Nuclear Cardiology, North American Society for Cardiac Imaging, Society for Cardiovascular Angiography and Interventions, and Society of Interventional Radiology[J]. J Am Coil Cardiol, 2006,48: 1475-1497.
  • 3Schwitter J, Wacker CM, van Rossum AC, et al. MR-IMPACT: comparison of perfusion-cardiac magnetic resonance with single-photon emission computed tomography for the detection of coronary artery disease in a multicentre, multivendor, randomized trial[J]. Eur Heart J, 2008,29: 480-489.
  • 4Brodoefel H, Burgstahler C, Tsiflikas I, et al. Dual- source CT: effect of heart rate, heart rate variability, and calcification on image quality and diagnostic accuracy [J]. Radiology, 2008,247: 346-355.
  • 5Meijboom WB, Meijs MF, Schuijf JD, et al. Diagnostic accuracy of 64-slice computed tomography coronary angiography: a prospective, multicenter, multivendor study[J]. J Am Coil Cardiol, 2008,52:2135-2144.
  • 6Carrigan TP, Nair D, Schoenhagen P, et al. Prognostic utility of 64-slice computed tomography in patients with suspected but no documented coronary artery disease [J]. Eur Heart J, 2009,30:362-371.
  • 7Gopal A, Nasir K, hhmadi N, et al. Cardiac computed tomographic angiography in an outpatient setting: an analysis of clinical outcomes over a 40-month period [J]. J Cardiovascular Comput Tomogr, 2009,3:90-95.
  • 8George RT, Arbab-Zadeh A, Miller JM, et ai. Adenosine stress 64- and 256-row detector computed tomography angiographyand perfusion imaging: a pilot study evaluating the transmural extent of perfusion abnormalities to predict atherosclerosis causing myocardial ischemia. Circ Cardiovasc Imaging. 2009;2:174 -182.
  • 9Peng J, Wu S-Y, Yeh BM, et al. Dual source dual energy CT of acute myocardial infarction: correlation with histopathological findings in a canine model. Invest Radiol. 2010;45:290-297.
  • 10Lell M, Marwan M, Schepis T, et al. Prospectively ECG- triggered high-pitch spiral acquisition for coronary CT angiography using dual source CT: technique and initial experience[J], gut Radiol, 2009,19:2576-2583.

二级参考文献17

  • 1Penelope R,Sensky,Norah M.Interpreting regional myocardial magnetic resonance imaging data:A new method for collation with angiographic findings in patients with coronary artery disease[J].Clin Radiol,2002,57:498-501.
  • 2Vogl TJ,Abolmaai ND,Diebold T,et al.Techniques for the detection of coronary atherosclerosis:multi-detector row CT coronary angiography.Radiology,2002,223(1):212-220.
  • 3Martuscelli E,Romagnoli A.Type of bypass conduits and assessment of patency and occlusion by MSCT coronary angiography.American Heart Association,2004,110(20):3234-3238.
  • 4Axel Kuettner,Torsten Beck,et al.Diagnostic accuracy of noninvasive coronary imaging using 16-detector slice spiral computed tomography with 188 ms temporal resolution.Journal of the American College of Cardiology,2005,45 (1):123-124.
  • 5Ulzheimer S,Kalender WA.Assessment of calcium scoring performance in cardiac computed tomography[J].Eur Radiol,2003,13:484-497.
  • 6Becker C,Knez A,Leber A,et al.Detection of coronary artery stenoses with multislice helical CT.J Comput Assist Tomography,2002,26:750-755.
  • 7曹丹庆 蔡祖龙主编.全身CT诊断学[M].北京:人民军医出版社,1996.475-477.
  • 8Mohiuddin Sm,Ravage CK,Esterbooks DJ,et al.The comparative safety and diagnostic accuracy of adenosine myocardial perfusion imaging in women versus men[J].Pharmacotherapy,1996,16:646-651.
  • 9陈盛祖.临床技术操作规范.核医学分册[M].北京:人民军医出版社,2004:110-112.
  • 10Briguofi C, Airoldi F, Morel N, et al. New pharmaeolo gieal protoeols to prevent or reduce contrast media nep hmpathy[J]. Minerva Cardioangiol, 2005,53 (1): 49-58.

共引文献50

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部