期刊文献+

400Hz屏蔽室滤波器与CE102测试

CE102 Test Related to Shielding Room Filters of 400 Hz
下载PDF
导出
摘要 讨论了CE102测试与400 Hz屏蔽室滤波器之间的问题,部分400 Hz屏蔽室滤波器不能把经过滤波器的电磁干扰抑制到允许的电平范围内,导致屏蔽室内传导环境电平不满足测试要求,使得CE102的测试结果出现较大误差;另一方面,400 Hz屏蔽室滤波器还会造成供电电压升高,影响CE102的测试结果。结合实际案例,分析得出多级滤波中的电容是电压抬升的主要原因,并给出了解决问题的建议。 The problems concerning CE102 test and shielding room fiher for 400 Hz power supply are discussed. For example, the conducted emission environmental level can not meet the requirements, because the shielding room filter for 400 Hz power supply are not able to control electromagnetic interference voltage within the confines of allowable level. The filter also leads to power supply voltage rise, which may greatly affects test results. Finally, the countermeasures are suggested based on practical cases.
出处 《安全与电磁兼容》 2013年第2期28-30,共3页 Safety & EMC
关键词 400Hz中频电源 屏蔽室滤波器 传导环境电平 电压升高 CE102 intermediate frequency power supply of 400 Hz shielding room filter conducted emission environmental level powersupply voltage rise CE102
  • 相关文献

参考文献1

  • 1信息产业部电子标准化研究所,中国船舶工业总公司701所.GJB152A一1997军用设备和分系统电磁发射和敏感度测量[S].北京:中国标准出版社,1997.