期刊文献+

分光光度法测定白酒中乙醇的含量 被引量:11

Determination of Ethanol Content in Liquor by Spectrophotometry
下载PDF
导出
摘要 根据乙醇可以被酸性高锰酸钾溶液氧化,使酸性高锰酸钾溶液吸光度降低的原理,建立了测定白酒中乙醇含量的新方法。结果表明,可以乙醇的量(C)与酸性高锰酸钾溶液吸光度的降低(△A)建立一个标准曲线,且△A与C成线性关系,Y=0.0478X+0.6239,R=0.9997,测定的线性范围为4.830~21.13 mg,方法检出限为0.0262 mg/mL,相对标准偏差为3.2%。 Based on the fact that ethanol can be oxidized by acidic potassium permanganate solution and further reduce the absorbance of acidic potassium permanganate solution, a new method to measure ethanol content in liquor had been developed. The experimental results suggested that the standard curve could be established based on the amount of ethanol (C) and absorbance reduction (AA) of the acidic potassium permanganate solution, and the linear relations of AA and C was: Y=0.0478X+0.6239, R=0.9997 in the range of4.830-21.13 mg with the detection limit of 0.0262 mg/mL, and the relative standard deviation was 3.2 %.
出处 《酿酒科技》 北大核心 2013年第5期102-104,共3页 Liquor-Making Science & Technology
基金 周口师范学院应用化学重点学科资助
关键词 分光光度法 测定 乙醇 spectrophotometry determination ethanol
  • 相关文献

参考文献7

二级参考文献8

  • 1GB12288-90,水果、蔬菜制品乙醇含量的测定[S].
  • 2Smola N, Urleb U. Analytica Chimica Acta, 2000, 410: 203-210
  • 3Yuan Hongfu(袁洪福),Lu Wanzhen(陆婉珍). Modern Scientific Instruments(现代科学仪器), 1998, (5): 6-8
  • 4Mroczyk W B, Michalski K M. Computers Chem., 1995, 19(3): 299-302
  • 5Wold S, Trygg J, Berglund A, Antti H. Chemometrics and Intelligent Laboratory Systems, 2001, 58: 131-150
  • 6Frost V J, Molt K. Journal of Molecular Structure, 1997, 410-411: 573-579
  • 7FuJianhang(傅建杭) SchlupJR.Acta Scientiarum Naturalium Universitatis Nankaiensis(南开大学学报 (自然科学)),1994,(1):94-100.
  • 8GB/T 5009-1996,食品卫生检验方法(理化部分)[S].

共引文献84

同被引文献126

引证文献11

二级引证文献49

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部