摘要 Objective:A novel portable and intelligent fluid resuscitation infuser is proposed in this paper. It satisfies the demands of long time use in harsh environment, such as traffic accident, natural disaster, battlefield, evacuation, pre-hospital emergency and so on. Methods:Miniature linear motor and liquid blood cartridge compose the pump body. It's based on the biological impedance method to measure and control, which resolve the disadvantage of traditional infuser device:large power dissipation, big size, AC power supply only and can't be use in field. The whole device weights 250 gram and sizes as two mobile phone together. Results:Model device experiment shows:six number 7 standard AAA size alkaline batteries will run the pump for approximately 8-10 h at 6 liters per hour; IV bag can be placed at any position of patient, even under the stretcher. Conclusion:It provides accurate and reliable intravenous infusion for first-aid treatment in Objective: A novel portable and intelligent fluid resuscitation infuser is proposed in this paper. It satisfies the demands of long time use in harsh environment, such as traffic accident, natural disaster, battlefield, evacuation, pre-hospital emergency and so on. Methods: Miniature linear motor and liquid blood cartridge compose the pump body. It's based on the biological impedance method to measure and control, which resolve the disadvantage of traditional infuser device: large power dissipation, big size, AC power supply only and can't be use in field. The whole device weights 250 gram and sizes as two mobile phone together Results: Model device experiment shows: six number 7 standard AAA size alkaline batteries will run the pump for approximately 8-10 h at 6 liters per hour; IV bag can be placed at any position of patient, even under the stretcher. Conclusion: It provides accurate and reliable intravenous infusion for fwst-aid treatment in field.
机构地区 Division of Equipment
出处 《Journal of Medical Colleges of PLA(China)》 CAS 2013年第2期100-106,共7页 中国人民解放军军医大学学报(英文版)
基金 Supported by the Second Batch of Projects of Army Medical Eleventh Five-Year Plan Research(08G084) Chongqing Key Scientific and Technological Projects(CSTC,2008AC5120)
关键词 输液装置 便携式 微机电系统 智能 注入器 输血 流体 设计 Micro-electro-mechanical system Blood transfusion infusion Miniature linear motor Air eliminate membrane Bio-logical impedance
  • 相关文献

参考文献2

二级参考文献11

  • 1Cook RD, Saulnier GJ, Gisser DG, et al. ACT3: a high-speed, high-precision electrical impedance tomograph [ J]. IEEE Trans Biomed Eng, 1994, 41(8) : 713 -722.
  • 2Smith RWM, Freeston IL, Brown BH. A real-time electrical impedance tomography system for clinical use-design and preliminary results [ J]. IEEE Trans Biomed Eng, 1995,42 (2): 133- 140.
  • 3Woo E J, Hua P, Tompkins WJ. A robust image reconstruction algorithm and its parallel implementation in electrical impedance tomography [J]. IEEE Trans Med Imaging, 1993, 12(2) : 137 -145.
  • 4Seagar AD, Baber DC, Brown BH. Theoretical limits to sensitivity and resolution in impedance imaging [J]. Clin Phys Physiol Meas, 1987, 8(Suppl. A): 13-31.
  • 5Avis NJ, Barber DC. Image reconstruction using non-adjacent drive configurations [J]. Physiol Meas, 1994, 15(Suppl.2A): 153- 160.
  • 6Malmivuo J, Plonsey R. Bioelectromagnetism [DB/OL]. http:// butler. cc. rut. fi/- malmivuo/bem/bembook/26/26. htm, 2006-04- 01/2007-04-28.
  • 7Avis N J, Barber DC. Adjacent or polar drive?: image reconstruction implications in electrical impedance tomography systems employing filtered back projection [A]. In: Proceedings of the Annual International Conference of the IEEE-EMBS[ C]. Paris: IEEE Press, 1992. 14: 1689-1690.
  • 8Kauppinen P, Hyttinen J, Malmivuo J. Sensitivity distribution simulations of impedance tomography electrode combinations [ J ]. Int J Bioelectromagnetism, 2005, 7( 1 ) : 344 - 347.
  • 9Kauppinen P, Hyttinen J, Malmivuo J. Sensitivity distribution visualizations of impedance tomography measurement strategies [ J]. Int J Bioelectromagnetism, 2006, 8(1) : 1 - 9.
  • 10Holder DS. Electrical impedance tomography methods, history and applications [M]. UK: Bristol, Inst Phys Pub, 2005.