期刊文献+

EQUIVALENT UNIFORM DOSE SENSITIVITY TO CHANGES IN ABSORBED DOSE DISTRIBUTION

EQUIVALENT UNIFORM DOSE SENSITIVITY TO CHANGES IN ABSORBED DOSE DISTRIBUTION
原文传递
导出
摘要 Treatment planning in external beam radiation therapy (EBRT) utilizes dose volume histograms (DVHs) as optimization and evaluation tools. They present the fraction of planning target volume (PTV) receiving more than a given absorbed dose, against the absorbed dose values, and a number of radiobiological indices can be computed with their help. Equivalent uniform dose (EUD) is the absorbed dose that, uniformly imparted, would yield the same biological effect on a tumor as the dose distribution described by the DVH. Uncertainty and missing information can affect the dose distribution, therefore DVHs can be modeled as samples from a set of possible outcomes. This work studies the sensitivity of the EUD index when a small change in absorbed dose distribution takes place. EUD is treated as a functional on the set of DVHs. Defining a Levy distance on this set and using a suitable expansion of the functional, a very simple expression for a bound on the variation of EUD when the dose distribution changes is found. This bound is easily interpreted in terms of standard treatment planning practice.
出处 《International Journal of Biomathematics》 2013年第1期129-142,共14页 生物数学学报(英文版)
关键词 Equivalent uniform dose DVH von Mises differential. 剂量分布 吸收剂量 均匀 敏感度 等价 生物学指标 评估工具 生物效应
  • 相关文献

参考文献25

  • 1G. T. Y. Chen, Dose volume histograms in treatment planning, Int. J. Radiat. Oncol.Biol. Phys. 14 (1998) 1319—1320.
  • 2B. Choi and J. O. Deasy, The generalized equivalent uniform dose function as a basisfor intensity-modulated treatment planning, Phys. Med. Biol. 47 (2002) 3579-3589.
  • 3L. Cozzi, L. M. Buffa and A. Fogliata, Comparative analysis of dose volume histogramreduction algorithms for normal tissue complication probability calculations, ActaOncol 39 (2000) 165-171.
  • 4G. A. Ezzell, J. M. Galvin, D. Low, J. R. Palta, I. Rosen, M. B. Sharpe, P. Xia,Y. Xiao, L. Xing and C. X. Yu, Guidance document on delivery, treatment planning,and clinical implementation of IMRT: Report of the IMRT Subcommittee of theAAPM Radiation Therapy Committee, Med. Phys. 30 (2003) 2089-2115.
  • 5F. Cutanda-Henriquez and S. Vargas-Castrillon, A novel method for the evaluationof uncertainty in dose-volume histogram computation, Int. J. Radiat Oncol. Biol.Phys. 70 (2008) 1263-1271.
  • 6F. Cutanda-Henriquez and S. Vargas-Castrillon, Confidence intervals in dose volumehistograms computation, Med‘ Phys. 37 (2010) 1545-1553.
  • 7P. J. Huber, Robust Statistics (John Wiley & Sons, New York, 1981).
  • 8International Commission on Radiation Units and Measurements, ICRU ReportNo. 50. Prescribing, recording, reporting, photon beam therapy, ICRU, WashingtonDC (1994).
  • 9International Commission on Radiation Units and Measurements. ICRU ReportNo. 62. Prescribing, recording and reporting photon beam therapy (Supplement toICRU Report 50) ICRU, Washington DC (1999).
  • 10JCGM 100:2008(E), Guide to the Expression of Uncertainty in Measurement, Inter-national Standards Organization, Geneva (2008).