摘要 SF6气体以其优异的绝缘性能和灭弧性能被广泛用于电气设备中,SF6电气设备密封性能是检验其可靠性的重要指标,是实现其安全稳定运行的前提条件。文章对目前常用的SF6电气设备密封试验方法进行分析,对包扎方法、包扎材料、检漏仪采样管道、检漏仪准确度检验、大型法兰面检漏进行改进,应用效果良好。 SF6 gas has been broadly used in electric equipment for its outstanding insulation and arc extinguish prop- erty, and its sealing property is an important index to testing its reliability, also it is the prerequisite to achieve safe and stable operation. The paper makes analysis on commonly used sealing test method for SF6 electric equipment, and makes improvement on binding up method and material, leakage detector sampling pipe, leak detector accuracy test and large scale flange face leakage detection, and it has favorable applying effect.
出处 《青海电力》 2013年第1期57-58,共2页 Qinghai Electric Power
关键词 SF6电气设备 泄漏检测 改进 SF6 electric equipment leakage detection improvement
  • 相关文献

参考文献3

二级参考文献10

  • 1徐卫东.SF6/N2混合气体断路器的检修[J].电工技术,2005(5):59-61. 被引量:1
  • 2GBJ 147-1990电气装置安装工程高压电器施工及验收规范[S].
  • 3GB 7674-2008额定电压72.5 kV及以上气体绝缘金属封闭开关设备[S].
  • 4GB 11023-1989高压开关设备六氟化硫气体密封试验方法[S].
  • 5宁夏电力公司预试规程2006版[G].2006.
  • 6GB 50150-2006电气设备交接试验标准[S].
  • 7DL/T 402-2007交流高压断路器订货技术条件[S].
  • 8DL/T596-1996.电力设备预防性试验规程[S].[S].,..
  • 9GB1984-2003.高压交流断路器[S].[S].,..
  • 10朱栋.SF_6电气设备检漏检测方法的探讨[J].宁夏电力,2008(C00):94-97. 被引量:10