期刊文献+

64排螺旋CT对单发肺小结节的诊断价值 被引量:8

下载PDF
导出
摘要 选取本院2010年1月~2011年1月22例单发肺小结节患者,结果经病理诊断恶性结节12例(转移瘤6例,周围型肺炎6例),良性结节10例(慢性非结节性炎性假瘤2例,肺动脉断面1例,结核球7例);64排螺旋检查诊断恶性结节11例,良性结节10例,未定性1例,诊断正确19例,错误2例。64排螺旋CT在单发肺小结节诊断方面的敏感性是83.33%,特异性是90%,准确性是86.36%。可见,64排螺旋CT在单发肺小结节的临床诊断上具有较高的敏感性、特异性、准确性,所以值得进一步在临床单发肺小结节临床诊断上推广。
作者 刘建华
出处 《现代诊断与治疗》 CAS 2013年第3期604-604,共1页 Modern Diagnosis and Treatment
  • 相关文献

参考文献4

二级参考文献18

  • 1刘士远,肖湘生.孤立性肺结节的处理策略[J].中华放射学杂志,2005,39(1):6-8. 被引量:93
  • 2[1]Fischbach F,Knollmann F,Griesshaber V,et al.Detection of pulmonary nodules by multislice computed tomography:improved detection rate with reduced slice thickness.Eur Radiol,2003,13(10):2378~2383
  • 3[2]Tsubamoto M,Johkoh T,Kozuka T,et al.Coronal multiplanar reconstruction view from whole lung thin-section CT by multidetector-row CT:determination of malignant or benign lesions and differential diagnosis in 68 cases of solitary pulmonary nodule.Radiat Med,2003,21(6):267~271
  • 4[3]Ko JP,Rusinek H,Jacobs EL,et al.Small pulmonary nodules:volume measurement at chest CT-phantom study.Radiology,2003,228(3):864~870
  • 5[4]Wormanns D,Kohl G,Klotz E,et al.Volumetric measurements of pulmonary nodules at multi-row detector CT:in vivo reproducibility.Eur Radiol,2004,14(1):86~92
  • 6[5]Kostis WJ,Reeves AP,Yankelevitz DF,et al.Three-dimensional segmentation and growth-rate estimation of small pulmonary nodules in helical CT images.IEEE Trans Med Imaging,2003,22(10):1259~1274
  • 7[6]Revel MP,Lefort C,Bissery A,et al.Pulmonary nodules:preliminary experience with three-dimensional evaluation.Radiology,2004,231(2):459~466
  • 8[7]Kostis WJ,Yankelevitz DF,Reeves AP,et al.Small pulmonary nodules:reproducibility of three-dimensional volumetric measurement and estimation of time to follow-up CT.Radiology,2004,231(2):446~452
  • 9[8]Takashima S,Sone S,Li F,et al.Indeterminate solitary pulmonary nodules revealed at population-based CT screening of the lung:using first follow-up diagnostic CT to differentiate benign and malignant lesions.AJR Am J Roentgenol,2003,180(5):1255~1263
  • 10[9]Takashima S,Sone S,Li F,et al.Small solitary pulmonary nodules (<or =1 cm) detected at population-based CT screening for lung cancer:Reliable high-resolution CT features of benign lesions.AJR Am J Roentgenol,2003,180(4):955~964

共引文献19

同被引文献74

  • 1李平,王蕴,宋广学,张辉,万淑红,顾涛,付占昭.CT引导下肺内大血管旁小病灶穿刺活检技术的临床应用[J].中国肿瘤临床,2007,34(8):462-464. 被引量:10
  • 2Ost D, Fein AM, Feinsilver SH. Clinical practice: the solitary pulmonary nodule[J]. N Engl J Med,2003,348:2535-2542.
  • 3Koike T, Togashi K, Shirato T, et al. Limited resection for noninvasive bronehioloalveolar carcinoma diagnosed by intraoperative pathologic examination [J]. Ann Thorac Surg, 2009,88(4) : 1106-1111.
  • 4Ohno Y, Hatabu H, Takenaka D, et al. CT-guided transthoracic needle aspiration biopsy of small (<or =20 turn) solitary pulmonary nodules[J]. A JR, 2003,180(6) : 1665-1669.
  • 5Yin L,Chen K,Guo L,et,al.Knee alignment in the transverse plane during weight-bearing activity and its implication for the tibial rotational alignment in total knee arthroplasty[J].Clin Biomech(Bristol,Avon),2015.15(1):13-17.
  • 6Matsuguma H, Yokoi K,Anraku M, et al. Proportionof ground-glass opacity on high-resolution computedtomography in clinical T1 NO MO adenocarcinoma ofthe lung: A predictor of lymph node metastasis [J]. JThorac Cardiovasc Surg,2002?124 : 278-284.
  • 7Yoon H E,Fukuhara K,Michiura T,et al. Pulmonarynodules 10 mm or less in diameter with ground-glass o-pacity component detected by high-resolution computedtomography have a high possibility of malignancy [J].Jph J Thorac Cardiovasc Surg,2005 ,53 :22-28.
  • 8Nakata M,Sawada S,Saeki H,et al. Prospective studyof thorac-oscopic limited resetion for ground-glass o-pacity selected by computed tomography[J]. Ann Tho-rac Surg,2003 ?75:1601-1605.
  • 9Lee H J,Goo J M, Lee C H,et al. Nodular ground-glass opacities on thin-section CT : Size change duringfollow-up and pathological results[J]. Korean J Radi-ol,2007,8:22-31.
  • 10Dobbins JT,Page MH,Jae-Woo S,et al.Digital tomosyn- thesis of the chest for lung nodule detection:interim sen- sitivity results from an ongoing NIH -sponsored trial[J].Medical Physics,2008,35(6):2554-2557.

引证文献8

二级引证文献92

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部