用于医学成像的碲锌镉单极型探测器研究进展 被引量:4

Progresses in the Development of CdZnTe Unipolar Sensing Detector For Medical Imaging
下载PDF
导出
摘要 碲锌镉(CdZnTe)半导体材料具有探测效率高、能量分辨率高和体积小重量轻的特点,是公认的最有希望成为下一代伽马射线探测装置的材料。然而,空穴俘获导致的电荷收集不完全限制了碲锌镉半导体探测器的性能。解决空穴俘获最有效的方法是单极型探测器技术。文章首先简要介绍半导体探测器中电荷收集的相关理论,然后重点阐述单极型探测器技术的实现方法,包括各种电极的结构设计原理、典型的探测器原型机介绍、性能特点及其结构设计的优缺点。最后简要展望了碲锌镉半导体探测器未来的发展方向。 The CdZnTe semiconductor is now regarded as the most promising candidate for the next generation of gamma ray detectors, providing good stopping power for gamma rays, lightweight camera heads and improved energy resolution. However, the performance of CdZnTe detector is limited mainly by incomplete charge collection problem resulted from hole trapping. Single charge sensing technique is the most effective way for solving the trapping problem with some electronic correction methods. Firstly, the methods and techniques for improving the performance summarized covering the of CdZnT in detail. principles e detectors were reviewed. Then the single charge sensing techniques were CdZnTe detectors of different geometries were discussed particularly, of the electrode geometry design, some detector prototypes development and special correction techniques to improve the energy resolution. Finally, future deve of CdZnTe detector is also discussed.
出处 《半导体光电》 CAS CSCD 北大核心 2013年第2期171-179,共9页 Semiconductor Optoelectronics
基金 国家重大仪器专项项目(2011YQ030114) 国家"973"计划项目(2011CB707500)
关键词 碲锌镉 空穴俘获 权重电势 电极设计 CdZnTe hole trapping weighting potential electrode design opment
  • 相关文献

参考文献67

  • 1Anger H 0.Scintillation camera [ J].Review ofScientific Instrum.,1958,29(1) ; 27-33.
  • 2Barber H B,Apotovsky B A,Augustine F L,et al.Semiconductor pixel detectors for gamma-ray imagingin nuclear medicine [J].Nucl.Instrum.MethodsPhys.Res.A,1997,395(3): 421-428.
  • 3Bradford B H.Applications of semiconductor detectorsto nuclear medicine [J].Nucl.Instrum.MethodsPhys.Res.A,1999,436(1):102-110.
  • 4Verger L,Boitel M? Gentet M C,et al.Characterization of CdTe and CdZnTe detectors forgamma-ray imaging applications [ J].Nucl.Instrum.Methods Phys.Res.A,2001,458:297-309.
  • 5Kaufman L,Ewins J,Rowan W,et al.Semiconductorgamma-cameras in nuclear medicine[J].IEEE Trans.Nucl.Sci.,1980,27(3):1073-1079.
  • 6Luke P N,Eissler E E.Performance of CdZnTecoplanar-grid gamma-ray detectors [J].IEEE Trans.Nucl.Sci.,1996,43:1481-1486.
  • 7Brunett B A,Van Scyoc J M,Schlesinger T E,et al.The spatial response of CdZnTe gamma-ray detectorsas measured by gamma-ray mapping [J].Nucl.Instrum,and Methods in Phys.Res.A,2001,458:76-84.
  • 8Luke P N,Amman M,Lee J S.Factors affectingenergy resolution of coplanar-grid CdZnTe detectors[J].IEEE Trans.Nucl.Sci.,2004,51:1199-1203.
  • 9Takahashi T,Watanabe S.Recent progress in CdTeand CdZnTe detectors [J].IEEE Trans.Nucl.Sci.,2001,48:950-959.
  • 10Shockley W.Currents to conductors induced by amoving point charge[J].J.Appl.Phys.,1938,9:635-636.

二级参考文献10

共引文献9

同被引文献39

  • 1曾国强,葛良全,赖万昌.手持式辐射仪高压直流电源的设计[J].电测与仪表,2008,45(6):46-49. 被引量:10
  • 2肖无云,魏义祥,艾宪芸.多道脉冲幅度分析中的数字基线估计方法[J].核电子学与探测技术,2005,25(6):601-604. 被引量:16
  • 3徐慧超,张金洲,沈浩元.用于X荧光分析的半导体探测器[J].常熟理工学院学报,2006,20(2):91-93. 被引量:3
  • 4Cremat Inc. CR-150-R5 evaluation board application guide[OL], http://www.cremat.com/CR- 150-BOX-R5.pdf, 2014.
  • 5Spieler H. Introduction to radiation detectors and electronics[R]. USA: Lawrence Berkeley National Laboratory, 1998.
  • 6Noulis T, Fikos G, Siskos S, et aL Noise analysis of radiation detector charge sensitive amplifier architectures[C]. Topical Workshop on Electronics for Particle Physics, 2008:486-489.
  • 7Femandes L M P, Simoes P C P S, dos Santos J M F. Digital rise-time discrimination of large-area avalanche photodiode signals in X-ray detection[J]. IEEE Transactions on Nuclear Science, 2002, 49(4): 1699-1703 DOI: 10.1109/TNS.2002.801518.
  • 8Toke J, Quinlan M J, Gawlikowicz W. A simple method for rise-time discrimination of slow pulses from charge-sensitive preamplifiers[J]. Nuclear Instruments and Methods in Physics Research, 2008, A595: 460-463. DOI: 10.1016/j.nima.2008.07024.
  • 9Niemela A, Sipila H, Ivanov V I. Improving CdZnTe X-ray detector performance by cooling and rise time discrimination[J]. Nuclear Instruments and Methods in Physics Research, 1996, A377(2): 484-486. DOI: 10.1016/0168-9002(96)00028-9.
  • 10Jordanov V T, Pantazis J A, Huber A C. Compact circuit for pulse rise-time discrimination[J]. Nuclear Instruments and Methods in Physics Research, 1996, A380: 353-357. DOI: 10.1016/0168-583X(94)00570-2.

引证文献4

二级引证文献18

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部