以某住宅小区为工程背景,对其水源热泵系统进行了可行性研究,并在地下水资源可用的前提下,探讨了水源热泵系统方案及其运行策略,对系统冷热负荷、冷热量平衡、工程初投资及运行费用等进行了计算分析,以保证系统高效、节能运行。
Taking some residential area as the engineering background, the paper undertakes the feasible research on its water source heat pump system, explores the scheme of the heat pump system and its operation strategies with the premise of the available underground water resource, and has the calculation and analysis of the cooling and heating load, the balance of cooling and heating, the primary investment of projects, and operation cost, so as to ensure the system to be efficient and energy-saving.
出处
《山西建筑》
2013年第16期112-115,共4页
Shanxi Architecture
关键词
地下水资源
抽水试验
回灌试验
负荷计算
underground water resource, pumping test, recharge test, loading calculation