摘要 目前影像科广泛使用的干式激光胶片成本高、速度慢、环境污染等问题日益突出,取而代之的是一种新型经济实用的纸质医疗影像输出系统将走上市场。本文通过对激光打印机结构和原理的介绍,简述了纸介质打印系统的应用价值和特点,分析了该系统在降低成本、提高效益、保护环境等方面的重要意义,提出了纸介质打印系统是未来医学影像资料打印的必然趋势和最佳选择。 In view of the increasingly serious problems resulted from the widely-used dry laser imager in medical imaging in the aspects of high cost, low efficiency and environmental pollution, a new and economical medical image paper printing system emerges and enters the medical market. Through introduction of the structure and principle of the system, this paper expatiates its characteristics, analyzes the significance in cost reduction, benefit enhancement and environmental protection and further explains that the system is an underlying trend and optimal choice for medical image print in the future.
出处 《中国医疗设备》 2013年第5期63-65,共3页 China Medical Devices
关键词 DICOM 激光胶片 纸介质打印系统 激光打印机 DICOM laser film paper printing system laser printer
  • 相关文献

参考文献15

二级参考文献33

共引文献45

同被引文献30

  • 1李昌领,张虹.DICOM医学图像胶片输出技术的实现[J].计算机工程与设计,2005,26(8):2226-2228. 被引量:4
  • 2刘虹,Cathy Lau.DICOM纸质医疗影像输出方案的应用前景及效益分析[J].医学综述,2007,13(2):150-153. 被引量:14
  • 3BI Reiner, EL Siegel, FJ Hooper,et al. Effect of film-based versus filmless operation on the productivity of CT tech- nologists[J]. Radiology, 1998,207(2) :481-485.
  • 4Schueller G,Kaindl E,Matzek WK,et a/.Image Quality of aWet Laser Printer Versus a Paper Printer for Full-Field Digital Mammograms [J] .A JR,2006,186( 1 ):38 -43.
  • 5Liang Z,Du X,Guo X,et al.Comparison of dry laser printer versus paper printer in full-field digital mammography[J].Acta Radiol,2010,51( 3 ):23 5-23 9.
  • 6Bley TA,Kotter E,Saueressig U,et a/.Using Receiver Operating Characteristic Methodology to Evaluate the Diagnostic Quality of Radiography on Paper Prints Versus Film[J]. A JR,2004,181 (6): 1487-1490.
  • 7赵书臣,孙晓红,张风雷,等.干式激光打印机在放射科数字化影像中的应用体会[J].医疗卫生装备,2010,31(4):383-384.
  • 8Choi Y, Kim JK,Lee HS,et al.Influence of intravenous contrast agent on dose calculations of intensity modulated radiation therapy plans for head and neck cancer[J].Radiother 0ncol,2006,81 (2): 158-162.
  • 9Buhr E,Gunther-Kohfahl S,Neitzel U.Simple method for modulation transfer function determination of digital imaging detectors from edge images[J].Proceeding of SPIE,2003,6(21):51-56.
  • 10McMenamin PG,Quayle MR,McHenry CR,et al.The production of anatomical teaching resources using three-dimensional(3D) printing technology[J].AnatSci Educ,2014,7(6):479-486.