摘要 目的:建立气体检测管法测定富氧空气中一氧化碳和二氧化碳的含量。方法:选择2个品牌的检测管,采用采样袋法和在线法2种取样方法,使用检测管分别测定高、中、低3个已知浓度的一氧化碳和二氧化碳标准气体(以高纯氮气为背景气体),考察方法的适用性,同时测定3家医院共6批样品的杂质含量。结果:一氧化碳和二氧化碳检测管测定标准气体的平均回收率在90%~110%之间,精密度(RSD)均小于4%,所有样品中的杂质均符合限度要求。结论:该方法简单快速,准确度高,精密度好,可用于富氧空气的质量控制。 Objective:To establish a gas detector tube method for the determination of carbon monoxide and carbon dioxide in oxygen - enriched air. Methods:Two brands of gas detector tubes were selected for the study coupledwith sampling bag and online sampling. Carbon monoxide and carbon dioxide standard gases at three levels (high, medium and low concentrations) ,with highpure nitrogen gas as the background gas ,were determined by gas detector tubes respectively to examine the applicability of the method. Overall, 6 tested batches of oxygen - enriched air from 3 hospitals were detected simultaneously by the proposed method. Results : The average recoveries of stand-ard gases tested by gas detector tubes for carbon monoxide and carbon dioxide ranged from 90% to 110%. The relative standard deviations of precision were all less than 4%. Impurities in all batches met the limit requirements.Conclusion:The method is simple and accurate with good precision, which is suitable for the quality control of oxygen - enriched air.
出处 《药物分析杂志》 CAS CSCD 北大核心 2013年第5期844-848,共5页 Chinese Journal of Pharmaceutical Analysis
基金 国家药典委员会国家药品标准提高研究项目
关键词 气体检测管 富氧空气质量控制 一氧化碳 二氧化碳 快速测定 gas detector tube oxygen - enriched air quality control carbon monoxide carbon dioxide rapid determination
  • 相关文献

参考文献9

  • 1USP. 34.3780.
  • 2EP. 7.1.3445.
  • 3JINMei-lan(金美兰),ZHAOJian-nan(赵建南).Standard Gas and Application(标准气体及其应用).Beijing(北京):Chemical Industry Press(化学工业出版社),2003.125.
  • 4林培川,张秀梅.高纯永久性气体中微量一氧化碳、甲烷和二氧化碳的甲烷转化法气相色谱法分析[J].低温与特气,2008,26(3):27-32. 被引量:17
  • 5张瑜,史黎薇,吴宜群,任改英,井海宁,孙承业.突发事件现场有毒气体检测方法评价[J].中国工业医学杂志,2010,23(5):339-342. 被引量:5
  • 6Tanaka Y, Nakamoto T, Moriizumi T. Study of highly sensitive smell sensing system using gas detector tube combined with optical sensor. Sens Actuators B Chem,2006,119 ( 1 ) : 84.
  • 7EP. 7.0.17.
  • 8McDermott HJ. Air Monitoring for Toxic Exposures. 2nd Ed. Moraga, US :John Wiley & Sons Inc ,2004. 407.
  • 9Charles S, McCammon, William EC, Herbert BC. The effect of ex- treme humidity and temperature on gas detector tube performance. Am Ind Hygiene Assoc J, 1982,43 ( 1 ) : 18.

二级参考文献11

  • 1GB/T18204.25-2000,纳氏试剂比色法[S].
  • 2GB/T18204.23-2000,不分光红外线气体分析仪法[S].
  • 3GB11742-89,聚乙烯醇磷酸氨-亚甲基蓝比色法[S].
  • 4GB7230-1987,气体检测管装置[S].
  • 5GB/T7445-1995.纯氢、高纯氢、超纯氢[S].[S].,..
  • 6GB/T 14599-93,高纯氧[S].
  • 7GB/T8980-1996高纯氮[S].
  • 8GB/T4844.3-1995高纯氦[S].
  • 9GB/T4842-2006高纯氩[S].
  • 10GB/T8984.3-1997气体中微量一氧化碳、二氧化碳和碳氢化合物总含量的测定气相色谱法[S].

共引文献20