期刊文献+

火焰原子吸收分光光度法测定工作场所空气中锌的不确定度评估

The Uncertainty Evaluation of Zinc in the Air of Workplace by Flame Atomic Absorption Spectrophotometric Method
下载PDF
导出
摘要 工作场所空气检测是职业危害因素评价的重要依据,依据CNAS-CL07:2006《测量不确定度评估和报告通用要求》,需对检测结果进行不确定度评估,为测量结果的准确性提供科学依据。文章讨论火焰原子吸收分光光度法测定工作场所中的锌不确定度评估。 Workplace air detection is an important basis for evaluation of occupation hazards,according to CNAS-CL07:2006 "Evaluation of the measurement uncertainty and the report of general requirements",required to evaluate the uncertainty of detection results,and provide scientific basis for the accuracy of measurement results.The paper discussed the uncertainty assessment of zinc in the workplace by flame atomic absorption spectrophotometric.
出处 《广东化工》 CAS 2013年第9期162-163,161,共3页 Guangdong Chemical Industry
关键词 火焰原子吸收分光光度法 不确定度分量 扩展不确定度 flame atomic absorption spectrophotometry uncertainty components expanded uncertainty
  • 相关文献

参考文献2

  • 1中国合格评定国家认可委员会.CNAS-GL06:2006《化学分析中不确定度的评估指南》[S].2006.
  • 2GBZ/T160.25.2004《工作场所空气有毒物质测定锌及其化合物》[S].