期刊文献+

高速CCD诊断MHD不稳定性的初步研究 被引量:2

Preliminary Study of the High-Speed CCD Diagnosis on MHD Instability
下载PDF
导出
摘要 电荷耦合器件(CCD)作为一种高灵敏度的二维辐射测量传感器,具有使用方便,测量结果可视性好等特点,近年来在托卡马克等离子体研究中得到广泛的应用.在HT-7和EAST托卡马克装置上建立了高速CCD成像诊断系统,并利用其进行磁流体力学(MHD)不稳定性研究.利用高速CCD成功观测到HT-7托卡马克上的锯齿振荡不稳定性和Mirnov振荡行为,以及EAST托卡马克H-mode过程中的边界局域模(ELM)行为,为进一步利用高速CCD诊断技术开展MHD不稳性时空过程的研究奠定了基础. Charge-coupled device (CCD) is widely used in Tokamak in recent years to measure the two dimensional radiations from plasmas owing to its sensitivity, easy to use and good data visualization. A high speed CCD diagnosis system has been set up and used to diagnose the MHD (magnetohydrodynamics) instabilitiy in HT-7 and EAST Tokamaks. Sawtooth and Mirnov oscillations in HT-7 Tokamak and ELM (edge-localized modes) process in EAST H-mode discharges are measured by CCD. The primary experimental results provide the base for further space and time evolution study of MHD instability by using high-speed CCD diagnosis.
出处 《东华大学学报(自然科学版)》 CAS CSCD 北大核心 2013年第2期247-254,250-252+254,共8页 Journal of Donghua University(Natural Science)
基金 国家自然科学基金资助项目(10775030,11105028) ITER国内配套资助项目(2009GB107006)
关键词 电荷耦合器件(CCD) 托卡马克 MHD不稳定性 charge-coupled device(CCD) Tokamak MHD instability
  • 相关文献

参考文献6

  • 1ALLEN A J, TERRY J L, GARNIER D, et al. The high resolution video capture system on the alcator C-Mod Tokamak [J]. Review of Scientific Instruments,1997,68(1) :947-950.
  • 2KIRK A, KOCH B,SCANNELL R,et al. Evolution of filament structures during Edge Localized Modes in the MAST Tokamak[J]. Physical Review Letters,2006,96(18) :185001.
  • 3HONG S H, GRISOLIA C, MONIER GARBET P. Development of automatic data extraction technique from visible CCD images for in-vessel dust study in Tore Supra[J]. Plasma Phys Control Fusion, 2009,51 (7) :075013.
  • 4NENIKA V, HLINA J, SONSKY J. Diagnostics of dynamic phenomena in thermal plasma lets by a CCD camera[J] IEEE Transaxtions on Plasma Science, 2005,33(2) : 418-419.
  • 5舒双宝,罗家融,薛二兵,等.HT-7托卡马克装置高速CCD成像系统的研究[J].微机计算机信息,2010,27(1):6-8.
  • 6高丽,庄革,胡希伟,朱孟周.J-TEXT托卡马克上的可见光CCD成像系统[J].科学技术与工程,2008,8(2):353-356. 被引量:6

二级参考文献4

  • 1郑银甲,冯震,罗萃文,施乐,陈燎原.HL-2A装置等离子体可见光成像系统[J].核聚变与等离子体物理,2004,24(4):259-264. 被引量:5
  • 2[1]Marmar E S,Boivin R L,Granetz R S,et al.High resolution visible continuum imaging diagnostic on and Alcator C-Mod tokamak.Bev Sci Instnun,2001;68:940-943
  • 3[3]Fenstennacher M E,Meyer W H,Wood R D,et al.Applications of visible CCD eflgner08 on and Alcator C-Mod tokamak.Rev Sci In.strum.2001;72:935-939
  • 4[4]Granetz R S,Smeulders P.X-ray tomography on JET.Nucl Fusion.1988:28;457-460

共引文献5