摘要 为了研究由后张预应力筋将预制梁柱拼装在一起形成的框架结构的抗震性能,在四榀梁柱中节点低周反复加载试验的基础上,采用弹塑性分析程序DRAIN-2DX进行了数值模拟分析,并根据截面的受力平衡条件,给出了试件力-位移关系曲线上的几个关键点——开裂点、线性极限点、屈服点和承载力极限点对应的梁端弯矩值的简化计算公式。研究结果表明:通过合理建模和选择模型参数,采用DRAIN-2DX程序可以较为准确地模拟出试件整个试验过程中的楼层剪力-层间位移角关系滞回曲线和骨架曲线,曲线上的几个关键点也与试验结果吻合较好,但计算曲线的初始刚度偏大;简化计算公式具有一定的精度,便于工程设计应用。 To evaluate the seismic performance of the concrete flame in which precast beams and columns are connected by post-tensioned tendons, numerical analysis of four beam-to-column assemblages which were tested under cyclic reversal loads was carried out using the software DRAIN-2DX. Then the simplified calculation formula of the beam end bending moment at several key points on the force-drift relation curve (including the cracking point, the linear limit point, the yielding point and the ultimate limit point) is derived based on principle of statically balancing. The analysis results indicate that the calculated shear force-drift hysteretic loops and the envelope curve agrees well with the experimental results, and the key points on the envelope curve are close to the experimental ones, while the analytical initial stiffness is relatively higher; the formula is proved to be effective and convenient for engineering application.
出处 《工程力学》 EI CSCD 北大核心 2013年第5期153-159,164,共8页 Engineering Mechanics
基金 国家自然科学基金青年科学基金项目(50908071 51278519)
关键词 预制 预应力 框架 梁柱节点 抗震性能 低周反复加载试验 数值模拟分析 简化计算公式 precast prestressed frame beam-column assemblages seismic performance low-cycle reversedload test numerical simulation analysis simplified calculation formula
  • 相关文献

参考文献12

  • 1种迅,孟少平,潘其健,张林振.预制预应力混凝土框架结构形式及设计方法研究[J].工业建筑,2006,36(5):5-8. 被引量:14
  • 2Stefano Pampanin, Nigel Priestley M J,Sritharan S.Analytical modeling of the seismic behavior of precastconcrete frames desinged with ductile connections [J].Journal of Earthquake Engineering, 2001, 5(3): 329-367.
  • 3Magdy T, El- Sheikh, Richard Sause. Seismic behaviorand design of unbonded post-tensioned precast concreteframes [J]. PCI Journal, 1999,44(3): 54-70.
  • 4Masahiro Sugata, Haruhiko Okamoto. Flexural strengthand deformation characteristics of precast prestressedconcrete beam-column connection with unbondedtendons [C]. Proceedings of the first FIB Congress,Osaka: Osaka Prefectural Government, 2002.
  • 5Prakash V,Powell G H,Campbell S. DRAIN-2DX baseprogram description and user guide [R]. TechnicalReport UCB/SEMM 1993/17, Department of CivilEngineering, University of California, Berkeley, 1993.
  • 6JGJ 101-96,建筑抗震实验方法规程[S].北京:中国建筑工业出版社,1996.
  • 7JGJ 101-96, Specification of testing methods forearthquake resistant buildings [S]. Beijing: ChinaArchitecture & Building Press, 1996.
  • 8吴京,孟少平.预应力混凝土极限抗弯承载力计算的等效荷载法[J].工业建筑,1999,29(9):24-28. 被引量:24
  • 9Mander J B,Priestley M J N, Park R- Theoretical stress-strain model for confined concrete [J]. Journal ofStructural Engineering, 1988,114(8): 1804-1827.
  • 10GB50010-2010,混凝土结构设计规范[s].北京:中国建筑工业出版社,2010.