期刊文献+

股骨近端防旋髓内钉螺旋刀片向内穿出的研究进展 被引量:12

原文传递
导出
摘要 股骨近端防旋髓内钉(proximal femoral nail antirotation,PFNA)是AO国际内固定研究学会在2004年发明的一种新型头髓钉,与治疗股骨转子周围骨折的其他头髓钉相比,其不但具有力臂短、强度大、创伤小等共同特点^[1-3],而且只用1枚螺旋刀片固定头颈骨块,兼具抗旋转和抗内翻能力,螺旋刀片通过敲击“挤入”股骨头,减少了骨量的丢失^[4-6]。
出处 《中华创伤骨科杂志》 CAS CSCD 北大核心 2013年第5期442-444,共3页 Chinese Journal of Orthopaedic Trauma
  • 相关文献

参考文献23

  • 1Adams Cl, Robinson CM, Court-Brown CM, et al. Prospective ran-domized controlled trial of an intramedullary nail versus dynamic screwand plate for intertrochanteric fractures of the femur. J Orthop Trauma,2001,15: 394-400.
  • 2Schipper IB, Marti RK, van der Werken C. Unstable trochanteric, femoral fractures: extramedullary or intramedullary fixation. Review ofliterature. Injury, 2004, 35: 142-151.
  • 3Herrera A, Domingo U, Calvo A, et al. A comparative study oftrochanteric fractures treated with the Gamma nail or the proximalfemoral nail. Int Orthop, 2002, 26: 365-369.
  • 4Lenich A, Vester H, Nerlich M, et al. Clinical comparison of thesecond and third generation of intramedullary devices for trochantericfractures of the hip-Blade vs screw. Injury, 2010,41: 1292-1296.
  • 5Mereddy P, Kamath S, Ramakrishnan M, et al. The AO/ASIFproximal femoral nail antirotation (PFNA): a new design for thetreatment of unstable proximal femoral fractures. Injury, 2009, 40:428-432.
  • 6Park JH, Lee YS, Park JW, et al. A comparative study of screw andhelical proximal femoral nails for the treatment of intertrochantericfractures. Orthopedics, 2010, 33: 81-85.
  • 7Brunner A, Jockel JA, Babst R, et al. The PFNA proximal femur nailin treatment of unstable proximal femur fractures—3 cases of postop-erative perforation of the helical blade into the hip joint. J OrthopTrauma, 2008, 22: 731-736.
  • 8Frei HC, Hotz T, Cadosch D, et al. Central head perforation, or “cutthrough,,,caused by the helical blade of the proximal femoral nailantirotation. J Orthop Trauma, 2012, 26: el02-el07.
  • 9Li X,Heffernan MJ, Kane C, et al. Medial pelvic migration of the lagscrew in a short gamma nail after hip fracture fixation: a case reportand review of the literature. J Orthop Surg Res, 2010,27: 5.
  • 10Baumgaertner MR, Curtin SL, Lindskog DM, et al. The value of thetip-apex distance in predicting failure of fixation of pertrochantericfractures of the hip. J Bone Joint Surg Am, 1995, 77: 1058-1064.

二级参考文献19

  • 1Gyarmati J,Gyarmati J Jr,Barabanova I,et al.On the clinical significance of the Singh-index[J].Radiol diagn,1978,19(5):584-590.
  • 2Cooper C,Barker DJ,Hall A J,et al.Evaluation of the Singh index and femoral calcar width as epidemiological methods for measuring bone mass in the femoral neck[J].Clinic Radiol,1986,37(2):123-125.
  • 3Singh M,Nagrath AR,Maini PS.Changes in trabecular pattern of the upper end of the femur as an index of osteoporosis[J].J Bone Joint Surg Am,1970,52(3):456-457.
  • 4Baumgaertner MR,Curtin SL,Lindskog DM,et al.The value of the tip-apex distance in predicting failure of fixation of peritrochanteric fractures of the hip[J].J Bone Joint Surg Am,1995,77(7):1058-1064.
  • 5Haidukewych GJ.Intertrochanteric fractures:Ten tips to improve results[J].Instr Course Lect,2010,59:503-509.
  • 6Haidukewych G J,Israel TA,Berry DJ.Reverse obliquity fractures of the intertrochanteric region of the femur[J].J Bone Joint Surg Am,2001,83(5):643-650.
  • 7Kyle RF,Cabanela ME,Russell TA,et al.Fractures of the proximal part of the femur[J].Instr Course Lect,1995,44:227-253.
  • 8Janzing HM,Houben BJ,Brandt SE,et al.The gotfried percutaneous compression plate versus the dynamic hip screw in the treatment of pertrochanteric hip fractures:minimal invasive treatment reduces operative time and postoperative pain[J].J Trauma,2002,52 (2):293-298.
  • 9Knight WM,DeLee JC.Nonunion of intertrochanteric fractures of the hip:a case study and review[J].Orthop Trans,1982,6:438.
  • 10Kosygan KP,Mohan R,Newman RJ.The gotfried percutaneous compression plate compared with the conventional classic hip screw for the fixation of intertrochanteric fractures of the hip[J].J Bone Joint Surg Br,2002,84(1):19-22.

共引文献19

同被引文献98

  • 1肖湘,张铁良,马宝通.“尖顶距”值与拉力螺钉切出股骨头关系的临床回顾性研究[J].中华创伤骨科杂志,2006,8(8):722-724. 被引量:42
  • 2朱江涛,卫小春.股骨粗隆间骨折分型[J].实用骨科杂志,2007,13(7):410-413. 被引量:69
  • 3李双,王栋,张世民.尖顶距与股骨头内拉力螺钉切出的研究进展[J].中国矫形外科杂志,2007,15(19):1484-1485. 被引量:25
  • 4Zhou JQ, Chang SM. Failure of PFNA: helical blade perforation and tip-apex distance. Injury, 2012, 43(7): 1227-1228.
  • 5Born CT, Karich B, Bauer C, et al. Hip screw migration testing: first results for hip screws and helical blades utilizing a new oscillating test method. J Orthop Res, 2011(29): 760-766.
  • 6Goffin JM, Pankaj P, Simpson AH, et al. Does bone compaction around the helical blade of a proximal femoral nail antirotation (PFNA) decrease the risk of cut-out? A subject-specific computational study. Bone Joint Res, 2013, 2(5): 79-83.
  • 7Nikoloski AN, Osbrough AL, Yates PJ. Should the tip-apex distance (TAD) rule be modified for the proximal femoral nail antirotation (PFNA)? A retrospective study. J Orthop Surg Res, 2013, 8: 35.
  • 8Bong MR, Kummer FJ, Koval KJ, et al. Intramedullary nailing of the lower extremity: biomechanics and biology. J Am Acad Orthop Surg, 2007, 15(2): 97-106.
  • 9Rosenblum SF, Zuckerman JD, Kummer FJ, et al. A biomechanical evaluationof the Gamma nail. J Bone Joint Surg (Br), 1992, 74(3): 352-357.
  • 10Bostrom MP, Lyden JP, Ernberg JJ, et al. A biomechanical evaluation of the long stem intramedullary hip screw. J Orthop Trauma, 1995, 9(1): 45-52.

引证文献12

二级引证文献135

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部