3.0T MR头颈部3D-TOF-MRA的临床应用 被引量:9

3.0T MR clinical application of 3D-TOF-MRA on head and neck
下载PDF
导出
摘要 目的评价3.0T磁共振成像MR三维时间飞跃法(3D-TOF-MRA)显示头颈部血管情况,探讨3D-TOF-MRA在头颈部血管病变的临床应用价值。方法对头颈部血管病变的30例病人进行3D-TOF-MRA检查,扫描范围自颅顶至主动脉弓。通过图像重建获得满意的头颈部三维动脉血管像。结果对临床头颈部血管疾病的患者30例行3D-TOMRA,对其图像质量和血管显示情况进行分析,所有图像均能满足诊断要求。结论 3D-TOF-MRA是可靠的快速的无创血管成像方法,在评估颈部血管、近端颅内血管方面,与DSA相比,具有良好的一致性。 Objective To evaluate3 D-TOF-MRA show blood vessels of head and neck and discuss the value of clini- cal application of 3D-TOF-MRA on vascular disease of head and neck. Methods Thirty patients suspected of having blood vessel diseases underwent 31~TOF-MRA,The satisfying 3D arterial image of head and neck in any position or ar- bitrary angle was obtained through 3D MIP resconstretion of the subtraction images and intergration of anteropisterior images,and evaluate the image quality and classify the degree of hemal stricture. Results 3INTOF-MRA were per- formed in 30 patients with suspected vascular disease of head and neck. The image quality and displaying of vessels were evaluated,all the images can satisfy the diagnosis requirements. Conclusion 3D-TOF-MRA is reliable and rapid method of the image of noninvasive blood vessels. Compared with DSA, there is a good consistency in the evaluation of the neck and proximal, intracranial vascular.
出处 《中国实验诊断学》 2013年第5期894-895,共2页 Chinese Journal of Laboratory Diagnosis
关键词 三维时间飞跃法(3D-TOF-MRA) 磁共振血管成像 数字减影血管造影(DSA) 头颈部血管 3D Time of flight Magnetic resonance angiography^digital subtraction angiography head and neck ves- sels
  • 相关文献

参考文献4

  • 1M arckm ann P,Skov L,Rossen K,et al. Nephrogenic systemic fi brosis:suspected causative role of gadodiamide used for contras tenhanced magnetic resonance imaging[J]. J Am Soc Nephro 2006,17:339.
  • 2尉传社,袁飞,顾欣,冯凯琳,龙淼淼,吴胜勇.3.0T MR颅脑的3D-TOF MRA[J].放射学实践,2005,20(10):897-900. 被引量:14
  • 3白敏,郭茜,狄玉进,徐金法,陈军,谢国华,李淑华,布春青.3.0T高场磁共振3D-TOF-MRA对头颈部血管变异的评价[J].临床放射学杂志,2011,30(5):640-643. 被引量:15
  • 4Chen YC,Sun ZK,Li MH,et al. The clinical value of MRA at 3. 0 T for the diagnosis and therapeutic planning of patients with subarachnoid haemorrhage[J]. Eur Radiol,2012,22(7) : 1404.

二级参考文献15

  • 1Marckmann P, Skov L, Rossen K, et al. Nephrogenic Systemic Fibro- sis:Suspected Causative Role of Gadodiamide Used for Contrast-en- hanced Magnetic Resonance Imaging. J Am Soc Nephrol,2006,17: 2339.
  • 2Krabbe-Havtkamp MJ, van der Grond J, Leeuw FE, et al. Circle of Willis:morphologic variation on three-dimensional time-of-flight MR angiograms. Radiology, 1998,207 : 103.
  • 3Henderson RD, Eliasziw M, Fox A J, et al. Angiographieally defined collateral circulation and risk of stroke in patients with severe carotid artery stenosis Stroke, 2000,31 : 128.
  • 4Uchino A, Kato A, Takase Y, et al. Basilar artery fenestrations detec- ted by MR angiography. Radiat Med,2001,19 :73.
  • 5Sander WP, Sorek PA, Mehta BA. Fenestration of intracranial arteries with special attention to associated aneurysms and other anomalies. AJNR, 1993,14:675.
  • 6Osborn AG. Diagnostic Cerebral Angiography. Philandelphia:Lippin- cott Williams &Wilkins,2000,91.
  • 7Van den Brink JS, Watanabe Y, Kuhl CK, et al. Implications of SENSE MR in Routine Clinical Practice[J]. Eur J Radiol, 2003,46(1) :3-27.
  • 8Al-Kwifi O, Emery DJ, Wilman AH. Vessel Contrast at Three Tesla in Time-of-Flight Magnetic Resonance Angiography of the Intracranial and Carotid Arteries[J]. Magn Reson Imag, 2002,20(2):181-187.
  • 9Bernstein MA, HustonJ,Lin C,et al. High-Resolution Intracranial and Cervical MRA at 3.0T:Technical Considerations and Initial Experience[J]. Magn Reson Med,2001,46(5) :955-962.
  • 10Wansapura J, Holland S,Dunn R,et al. NMR Relaxation Times in the Human Brain at 3 Tesla[J]. Magn Reson Imag, 1999,9 (4):531-538.

共引文献25

同被引文献81

引证文献9

二级引证文献50

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部