期刊文献+

注浆与抹面相结合治理某住宅楼地下室渗漏 被引量:1

Leakage Treatment for a Building Basement Combined with Grouting and Plastering
下载PDF
导出
摘要 某住宅楼地下室外墙柔性防水层设计采用聚乙烯丙纶防水卷材,底板无柔性防水设计,出现渗漏后,治理时采用了注浆和抹面相结合的工艺,即:地下室底板浇筑混凝土刚性防水层,地下室垫层、外墙灌注聚氨酯灌浆材料,地下室内刮涂ER防水防腐胶泥,取得了预期效果。 Polyethylene-polypropylene waterproofing membrane is used in the waterproofing design of the external walls of basements of a residential building, nevertheless there is no flexible waterproofing layer on the bottom plates. After the leakage appeared, grouting and plastering are used for the treatment. Waterproofing concrete is applied on the bottom plates. Polyurethane grouting material is used for the cushion course and external walls of the basement. ER waterproofing anticorrosion mortar is plastered on internal wails of the basement. All these measures get their expected results.
出处 《中国建筑防水》 2013年第10期39-41,共3页 China Building Waterproofing
关键词 地下室 渗漏治理 聚氨酯灌浆材料 ER防水防腐胶泥 basement leakage treatment polyurethane grouting material ER waterproofing anticon'osion mortar
  • 相关文献

参考文献2

二级参考文献4

  • 1李承刚.论建筑防水的多元化[J].中国建筑防水,2005(12):4-6. 被引量:3
  • 2王铁梦.化学灌浆是工程结构裂缝控制的重要组分是工程质量的最后保证[C]//中国重庆首届化学灌浆与防水堵漏裂缝技术控制技术研讨会论文集,2006.
  • 3JC474--2008砂浆、混凝土防水剂[S].北京:中国建材工业出版社.2008.
  • 4GB50367--2006混凝土结构加固设计规范(附录A)[S].北京:中国建筑工业出版社,2006.

共引文献13