摘要
探讨了动态供电拓扑下的线损率的计算方法,即基于分段计算的线损率计算模型,并结合上海某供电公司线损管理工作现状,对线路割接中的线损率计算做了研究,是对供电企业所面临的工作和挑战的一次探索。
The line loss rate calculation method basing on dynamic power supply topology was discussed, that is sub- section based cellculation model. Combined with management situation of a power supply company in Shanghai, the line loss rate calculation was studied during network cutover.
出处
《华东电力》
北大核心
2013年第5期1090-1092,共3页
East China Electric Power
关键词
动态拓扑
分段计算
节能降损
dynamic topology
subsection calculation
energy-saving and losses-reducing