期刊文献+

大鼠肝窦内皮细胞扫描电镜制样方法的改良

Modified sample preparation method for scanning electron microscopy of rat liver sinusoidal endothelial cells
下载PDF
导出
摘要 目的:改良大鼠肝窦内皮细胞扫描电镜制样方法,以期得到优质图像。方法:采用红细胞裂解液去除红细胞,然后样本划痕制作断裂面的方法制备电镜样本。结果:改良法可清晰观察肝窦内皮细胞的窗孔。结论:通过裂解红细胞和样本划痕的方法制备样本,可以获得优质肝窦内皮细胞扫描电镜图像。 Objective; To improve the sample preparation method for scanning electron microscopy of rat liver sinusoidal endothelial cells. Methods: The erythrocytes were removed by erythrocyte lysis buff- er. Samples were prepared by scratching method. Results. Fenestrae in rat liver sinusoidal endothelial cells could be observed clearly by the modified method. Conclusion- We can get scanning electron microscope image of rat liver sinusoidal endothelial cells with high quality by lysis of erythrocytes combined with sampie scratching.
出处 《海南医学院学报》 CAS 2013年第7期882-884,共3页 Journal of Hainan Medical University
基金 中国高校医学期刊临床专项资金项目(112210697)~~
关键词 肝窦内皮细胞 扫描电镜 红细胞 Liver sinusoidal endothelial cells~ Scanning electron microscope~ Erythrocyte
  • 相关文献

参考文献4

  • 1Khimmaktong W, Petpiboolthai H, Panyarachun B, et al. Anupunpisit V Study of curcumin on microvascula- ture characteristic in diabetic rat's liver as revealed by vascular corrosion east/scanning electron microscope (SEM) technique[J]. J Med Assoc Thai, 2012,95 (1 5) : 133-141.
  • 2Yoshida K,Yasuda M, Nasu T,et al. Scanning electron microscopic study of vascular and biliary casts in chick- en and duck liver[J]. J Vet Med. Sci, 2010,72 (7): 925- 928.
  • 3朱飞叶,陈国中,徐珊.化痰行瘀汤对肝纤维化大鼠肝脏超微结构的影响[J].中华中医药杂志,2012,27(6):1658-1660. 被引量:3
  • 4巩文玉,刘怡,李蓓,张瑞东,李志刚,吴敏媛.红细胞裂解液对CD34^+细胞相对计数的影响[J].中国实验血液学杂志,2010,18(3):762-765. 被引量:8

二级参考文献18

  • 1张国梁,戴敏,许钒,汪电雷,方朝晖,查安生,胡闻.软肝饮对免疫性肝纤维化大鼠细胞因子及肝细胞超微结构的影响[J].中医杂志,2006,47(3):219-221. 被引量:8
  • 2万岁桂,苏力,孙雪静,冀冰心,刘聪艳,贺景娟,徐娟,田丁.ProCOUNT与单平台ISHAGE方法检测外周血及采集物中CD34^+细胞绝对计数的比较[J].首都医科大学学报,2006,27(4):504-508. 被引量:4
  • 3薛博瑜,胡荣昕,孙丽霞.中医药治疗肝纤维化临床研究思路探讨[J].中华中医药杂志,2007,22(8):540-542. 被引量:23
  • 4Barnett D, Janossy G, Lubenko A, et al. Guideline for the flow cytometric enumeration of CD34 + Haematopoietic stem cells. Clin Lab Haematol, 1999 ; 21 ( 5 ) : 301 - 308.
  • 5Oelschlaegel U, Bornhaeuser M, Thiede C, et al. HPC enumeration with the Sysmex XE-2100 can guide further flow cytometric CD34^+ measurements and timing of leukaphereses. Cytotherapy, 2003; 5 (5) :414 -419.
  • 6Menendez P, Redondo O, Rodriguez A, et al. Comparison between a lyse-and-then-wash method and a lyse-non-wash technique for the enumeration of CD34^+ hematopoietic progenitor cells. Cytometry, 1998 ;34 (6) :264 - 271.
  • 7Macey MG, McCarthy DA, Milne T, et al. Comparative study of five commercial reagents for preparing normal and leukaemic lymphocytes for immunophenotypic analysis by flow cytometry. Cytometry, 1999 ;38 (4) : 153 - 160.
  • 8Stewart JC, ViUasmil ML, Frampton MW. Changes in fluorescence intensity of selected leukocyte surface markers following fixation. Cytometry, 2007 ; 71 (6) :379 - 385.
  • 9Levering WH, Preijers FW, van Wieringen WN, et al. Flow cytometric CD34^+ stem cell enumeration: lessons from nine years' external quality assessment within the Benelux countries. Cytometry B Clin Cytom, 2007; 72(3) : 178 -188.
  • 10Keeney M, Chin-Yee I, Weir K, et al. Single platform flow cytometric absolute CD34^+ cell counts based on the ISHAGE guidelines. International Society of Hematotherapy and Graft Engineering. Cytometry, 1998; 34(2) : 61 -70.

共引文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部