摘要
用有限差分法计算了三峡永久船闸闸室混凝土底板的温度场 ,考虑了分层浇筑的影响以及水管初期通水冷却和水管中后期通水冷却的效果 .对其应力场进行了分析 .推荐了比较有效的温控措施 .
Temperatures are calculated for the ship lock concrete base slab in the Changjiang Gorges by use of finite difference method. The effects of layered construction and pipe cooling in initial and later stages are taken into account. Thermal stresses are analyzed and a comparatively effective temperature control measure is recommended.
出处
《华北水利水电学院学报》
2000年第3期8-11,共4页
North China Institute of Water Conservancy and Hydroelectric Power
基金
中国长江三峡工程开发总公司资助项目!(CT - 99- 3- 5 )
关键词
水管冷却
温度场
应力场
混凝土底板
三峡船闸
pipe cooling
finite difference method
temperature fields
stress fields