期刊文献+

宝石CT前瞻性与回顾性冠脉成像的剂量对比分析

原文传递
导出
摘要 目的对比分析前瞻性和回顾性心电门控宝石CT冠状动脉成像时辐射剂量及图像质量的差异,为临床低剂量冠状动脉CT成像扫描方案的制定提供参考依据。方法回顾性分析216例宝石CT冠脉成像资料,前瞻性门控扫描组116例,回顾性门控扫描组100例,采用ECG管电流自动调制技术及螺距~心率自动匹配技术。分析两组检查在图像质量和有效辐射剂量方面差异。结果前瞻性心电门控扫描的辐射剂量可较回顾性心电门控扫描减少68.2%;但两组图像质量无明显差别。结论前瞻性心电门控与回顾性心电门控扫描均能保证冠状动脉成像质量,但前瞻性心电门控扫描显著地减少了有效辐射剂量。
出处 《中国辐射卫生》 2013年第1期115-117,共3页 Chinese Journal of Radiological Health
  • 相关文献

参考文献4

  • 1王锡明,武乐斌,李振家,柳澄,陈海松.64层螺旋CT在冠状动脉造影中的应用[J].中华放射学杂志,2005,39(11):1201-1204. 被引量:151
  • 2Hsieh J,Londt J, Vass M,et al. Step - and - shoot data ac- quisition and reconstruction for cardiac x - ray computed to- mogmphy [J]. Med Phys,2006,33( 11 ) :4 236 -4 248.
  • 3Van Hoe LR, De Meerleer KG, Leyman PP, et al. Coronary ar- tery calciumscoring using ECG - gated multidetector CT: effect of individuallyoptimized image -reconstruction windows on image quality andmeasurement reproducibility [ J]. Am J Ro- entgenol, 2003, 181 (6) :1 093 - 1 099.
  • 4王妍焱,吴国庚,周诚,高建华,焦晟,曹会志.64层螺旋CT前门控冠状动脉横断面扫描低剂量技术的初步研究[J].中华放射学杂志,2008,42(10):1018-1021. 被引量:79

二级参考文献13

  • 1邵广瑞,柳澄,刘延军,王道萍.多层螺旋CT与选择性冠状动脉造影对照研究及其临床应用[J].中华放射学杂志,2003,37(9):805-808. 被引量:80
  • 2张森,杜湘珂,李剑颖.心电图调制电流对于容积CT心脏扫描图像质量及曝光剂量影响的评估[J].中华放射学杂志,2006,40(9):974-976. 被引量:45
  • 3Trabold T, Buchgeister M, Kuttner A, et al. Estimation of radiation exposure in 16-detector row computed tomography of the heart with retrospective ECG-gating. Rofo, 2003, 175 : 1051-1055.
  • 4Mallet NR, Cademartiri F, van Mieghem CA, et al. High- resolution spiral computed tomography coronary angiography in patients referred for diagnostic conventional coronary angiography. Circulation, 2005,112 : 2318-2323.
  • 5Flohr TG, Schoepf U J, Kuettner A, et al. Advances in cardiac imaging with 16-section CT systems. Acad Radiol, 2003, 10: 386-401.
  • 6Hsieh J, Londt J, Vass M, et al. Step-and-shoot data acquisition and reconstruction for cardiac X-ray computed tomography. Med Phys, 2006,33:4236-4248.
  • 7Ritchie CJ, Godwin JD, Crawford CR, et al. Minimum scan speeds for suppression of motion artifacts in CT. Radiology , 1992, 185:37-42.
  • 8Rubin GD, Silverman SG. Helical (spiral) CT of the retroperitoneum. Radiol Clin North Am, 1995,33:903z932.
  • 9Becker CR, Knez A, Ohnesorge B, et al. Imaging of noncalcified coronary plaques using helical CT with retrospective ECG gating.A JR,2000,175:423-424.
  • 10Hong C, Becker CR, Huber A, et al. ECG-gated reconstructed multi-detector row CT coronary angiography : effect of varying trigger delay on image quality. Radiology,2001,220:712 -717.

共引文献225

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部