期刊文献+

金隆转炉送风机的噪声机理分析及治理 被引量:1

JinLong Converter Blower Noise Mechanism Analysis and Management
下载PDF
导出
摘要 金隆铜业公司的二台转炉送风机在运行过程中产生的噪音存在超标现象,影响员工的身心健康,通过对送风机噪声产生的机理、分布状况、降噪的方法和途径等方面的分析,针对性的采用增设有隔音、吸声效果的隔音室,使现场噪声值达到了工业指标要求;结合现场情况,对隔音室的要求及注意事项、材料选择等方面进行了详细的阐述。 Two converter blowers of Jinlong Copper Company make any noise which with excessive phenomenon in the operation process. It affects the physical and mental health of employees. Through analyzing the blower noise generation mechanism, distribu- tion, method and way of noise reduction, adopting adding sound insulation room of sound absorption effect, the site noise has been reached the industrial index requirements. Combined with the site situation, requirements to the sound insulation room, matters nee- ding attention and material selection etc are expounded in detail.
作者 丁士文
出处 《铜业工程》 CAS 2013年第2期56-60,83,共6页 Copper Engineering
关键词 风机 噪声分析 降噪 治理方案 工业指标 blower noise analysis noise reduction management scheme industrial index
  • 相关文献

参考文献5

二级参考文献1

  • 1北京有色冶金设计研究总院.采暖通风与空气调节设计规范[M]中国计划出版社,1989.

共引文献10

同被引文献2

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部