摘要
叙述了在市电停电后用PWN2-12型柴油机组发电,运行不久出现停机的故障处理方法。从案例实际出发,结合理论知识对柴油发电机组因缺机油而导致高温拉缸现象进行了全面的分析。
The paper described PWN2-12 diesel generating set in a monitoring oil room when power was cut off and the methods of trouble shooting causing shutting down shortly after its running. From the actual cases, combined with the the- oretical knowledge of diesel generator engine, a fully analysis of the phenomenon of high temperature cylinder caused by the lack of oil was performed.
出处
《通信电源技术》
2013年第3期64-65,共2页
Telecom Power Technology
关键词
柴油发电机组
缺油拉缸
故障处理
diesel generating set
lack of oil cylinder