期刊文献+

宁夏电网变电设备油中糠醛含量普查检测分析

Detection and analysis on furfural content in transformer equipment oil of Ningxia Power Grid
下载PDF
导出
摘要 采用高效液相色谱法对宁夏电网110 kV以上百余台在役电力变压器和互感器设备油样中的糠醛含量进行普查检测。根据糠醛普查含量检测结果,确定了变压器运行年限、绝缘纸老化速度与糠醛含量呈直线的关系。通过试验提出某主变压器不明杂峰出现与变压器故障具有紧密关系的观点,为今后研究变压器老化故障的判断提供了第一手资料。 Using high effective liquid chromatography make census and detection on furfural con- tent in hundreds of transformer mutual inductor equipments oil for aabove 110 kV Ningxia Power Grid, Based on the detection results of furfural content, determins the service life of transformer opera- tion and ageing speed of insulated paper show straight-line relationship with furfural content. The test shows that unnamed pear appearing in a main transformer has close relationship with transformer fail- ure, which provides the first hand material for old ageing failure diagnosis of the transformer.
作者 徐玲 俞力
出处 《宁夏电力》 2013年第2期63-66,共4页 Ningxia Electric Power
关键词 变压器 糠醛 检测 transformer furfural content detection
  • 相关文献

参考文献6

二级参考文献18

  • 1杨成德.糠醛精制法生产变压器油的工艺研究[J].应用化工,2005,34(4):254-255. 被引量:3
  • 2董志刚.变压器的噪声(2)[J].变压器,1995,32(11):27-31. 被引量:30
  • 3路长柏.电力变压器绝缘技术[M].哈尔滨:哈尔滨工业大学出版社,1998..
  • 4Dong M.Aging diagnosis of solid insulation for large oil-immersed oower transformers[C].Elect Insul.& Dielect Phen.2002 Annual Report Conference,2002:400-403.
  • 5Emsley A M,Xiao Heywood R J,Degradation of cellulosic insulation in power transformers[J].IEE Proc.-Sci.Meas.Technol.,2000,147(3):115-119.
  • 6Mechefske C K.Correlating power transformer tank vibration characteristics to winding looseness[J].Insight:Non-Destructive Testing and Condition Monitoring,1995,37(8):599-604.
  • 7于世林.高效液相色谱方法及应用[M].化学工业出版社,2006.5.
  • 8Q/HB14701-2008华北电网有限公司电力设备交接和预防性试验规程[S].
  • 9王钰,李彦明,张成良.变压器绕组变形检测的LVI法和FRA法的比较研究[J].高电压技术,1997,23(1):13-15. 被引量:57
  • 10DL/T596-1996.电力设备预防性试验规程[S].[S].,..