摘要 污泥浓度作为城市污水处理厂设计和运行管理过程的一个重要参数,目前主要采用重量法测定,该方法在应用过程中最大的缺点是耗时耗能.本研究采用分光光度法在OD600处测定活性污泥的浓度,建立测定的方法,优化测定的预处理条件,并对测定结果进行了误差分析.结果表明,分光光度法测定活性污泥浓度的较佳范围为0.996~3.864g/L,较佳的稀释液和空白应为超纯水,预处理的最佳条件为功率110W时超声处理4min.总之,分光光度法具有节能、省时、误差小的特点,是一种简单实用的污泥浓度测定方法. The suspended solid concentration in mixed liquid (MLSS) of activated sludge is an important parameter for designing and operating a wastewater treatment plant and is usually determined by gravimetric analysis, which is time-consuming and energy-consuming. This paper aimed to apply a procedure based on spectrophotometric analysis for rapid quantifying MLSS concentration of activated sludge at the wavelength of OD600. The pretreatment condition was optimized and measurement error was analyzed later after a detailed recipe was proposed. The results showed that the preferable range of activated sludge concentration ranged between 0. 9960-3. 864gMLSS/L. As for the diluent and blank in the spectrophotometric analysis, deionized water was favored. Meanwhile the optimal condition of ultrasonic pretreatment was under ll0W for 4 minutes. Compared with gravimetric method, spectrophotometrie analysis is a time-thrift, energythrift, low error method to determine the suspended solid concentration of activated sludge.
出处 《西安建筑科技大学学报(自然科学版)》 CSCD 北大核心 2013年第2期253-256,263,共5页 Journal of Xi'an University of Architecture & Technology(Natural Science Edition)
基金 国家自然科学青年基金(51108368) 陕西省科技计划国际合作项目(2011KW-34) 榆林市科技计划项目
关键词 污泥浓度 分光光度法 快速测定 节能 Concentration of activated sludge Spectrophotometric method Rapid Determination Energy-saving
  • 相关文献

参考文献8

  • 1国家环境保护总局《水和废水监测分析方法》编委会.水和废水监测分析方法[M].四版.北京:中国环境科学出版社,2002:100-284.
  • 2State Environmental Protection Administration of China. Monitoring and Analysis Method of Water andWastewater [M]. 4th ed. Beijing: China Environmental Science Press,2002.
  • 3LAPINSKI J , TUNNACLIFFE A. Reduction of suspended biomass in municipal wastewater using bdelloid rotifers[J]. Water Research, 2003(37) : 2027-2034.
  • 4BAO Lin-lin,LI Dong,LI Xiang-kun,HUANG Rong-xin,ZHANG Jie,LV Yang,XIA Guang-qing.Phosphorus accumulation by bacteria isolated from a continuous-flow two-sludge system[J].Journal of Environmental Sciences,2007,19(4):391-395. 被引量:15
  • 5LARSEN B S,KARAKASHEV D,ANGELIDAKI I,et al. Ex-situ bioremediation of polycyclic aromatic hydro-carbons in sewage sludge [J]. Journal of Hazardous Materials, 2009( 164): 1568-1572.
  • 6CHENG Xi-Yu, LI Qian, LIU Chun-Zhao. Coproduction of hydrogen and methane via anaerobic fermentation ofcornstalk waste in continuous stirred tank reactor integrated with up-flow anaerobic sludge bed [J]. BioresourceTechnology, 2012(114):327-333.
  • 7CHU C P,CHANG B,LIAO G S, et al. Observations on changes in ultrasonically treated waste-activated sludge[J]. Water Research, 2001,35(4) : 1038-1046.
  • 8ZHANG Pan-yue,ZHANG Guang-ming,WANG Wei. Ultrasonic treatment of biological sludge; Floe disintegra-tion, cell lysis and inactivation [J]. Bioresource Technology. 2007(98): 207-210.