摘要
针对某厂废气处理装置产品气往复式压缩机连杆螺栓断裂故障,从机组安装及运行出发,结合拆检情况、螺栓断口及受力等综合分析了故障产生原因。
In view of product for waste gas treatment unit of first. Then bolt fracture stress gas reciprocating compressor connecting-rod bolt fracture failure a refinery, was analyz ed e installation and operation combining the overhauling cause was comprehensive analyzed and provided finally. status were detailed at condition. The failure
出处
《石油化工设备》
CAS
2013年第3期110-113,共4页
Petro-Chemical Equipment
关键词
废气处理装置
往复式压缩机
连杆螺栓
断裂
waste gas treatment unit
reciprocating compressor
connecting-rod bolt
fracture