期刊文献+

地热闪蒸-双工质联合发电系统最佳参数选择 被引量:1

Optimal Parameter Selection of Geothermal Flash-binary Power System
原文传递
导出
摘要 介绍了地热闪蒸-双工质联合发电方式,通过数学模拟,分析地热水温度对单位热水发电量、热效率和最佳温度的影响,计算结果表明,地热水温度为80℃时,闪蒸系统采用直接冷却和间接冷却方式的联合发电系统的单位热水净发电量分别为1.08和0.86kW·h/t,地热水温度为150℃时,闪蒸系统采用直接冷却和间接冷却方式的联合发电系统的单位热水净发电量分别为6.57和6.35kW·h/t;采用直接冷却方式的联合发电系统的发电量以闪蒸发电为主,采用间接冷却方式的联合发电系统的发电量以双工质发电为主;当热源温度为100、130和150℃时,采用直接冷却和间接冷却方式的联合系统的最佳温度分别为80和85℃、100和115℃、125和140℃。地热闪蒸-双工质联合发电技术可以为中国中低温地热资源开发提供技术支撑。 The flash-binary system includes the single flash power system and the binary cycle system. The flash-binary power system enhances the production as compared with the single flash power system. In addition, compared with the two-stage flash power system, the single flash-binary power system can avoid some problems, such as the bulky equipments, the difficult installment and the high cost. Based on the numerical simulation, the effect of the geothermal water temperature on the net power output, the thermal efficiency and the optimal temperature of the flash-binary power system are discussed in this paper. The simulation results show that, when the temperature is 80℃, the net power output per geofluid is about 1.08 and 0.86kW-h/t by the direct cooling and the indirect cooling of the flash system, respectively; when the temperature is 150℃, the values are 6.57 and 6.35kW.h/t; when the geothermal water temperatures are 100, 130 and 150℃, the optimal temperatures of the combined system are 80 and 85℃, 100 and 115℃, 125 and 140℃ by the direct cooling and the indirect cooling of the flash system, respectively. In addition, the power output of the flash-binary system by the direct cooling is dominated by the flash power generation, while that by the indirect cooling is dominated by the binary power generation. The flash-binary power system could provide a technical support for the geothermal resource utilization in China.
出处 《科技导报》 CAS CSCD 北大核心 2013年第15期39-43,共5页 Science & Technology Review
基金 国家科技支撑计划课题(2012BAB12B01) 国家高技术研究发展计划(863计划)项目(2012AA053003)
关键词 地热发电 闪蒸-双工质联合发电 最佳温度 参数选择 geothermal power flash-binary power system optimal temperature parameter selection
  • 相关文献

参考文献19

  • 1Bertani R. Geothermal power plant in the world 2005 -2010 updatereport[J]. Geothermics, 2012, 41: 1-29.
  • 2汪集暘,马伟斌,龚宇烈,等.地热利用技术[M].北京:化学工业出版社,2004,98-100.
  • 3Luo C, Huang L C, Gong Y L,et al. Thermodynamic comparison ofdifferent types of geothermal power plant systems and case studies inChina[J]. Renewable Energy, 2012, 48: 155-160.
  • 4Pasek A D, Soelaiman T A F, Gunawan C V. Thermodynamics study offlash-binary cycle in geothermal power plant [J]. Renewable andSustainable Energy Reviews, 2011, 15: 5218-5223.
  • 5Michaelides E E, Scott G J. A binary-flashing geothermal power plant[J].Energy, 1984,9(4): 323-331.
  • 6Jalilinasrabadya S, Itoia R,Valdimarsson P, et al. Flash cycle optimizationof Sabalan geothermal power plant employing exergy concept [J].Geothermics, 2012, 43: 75-82.
  • 7Rosyid H, Koestoer R. Sensitivity annlysis of steam power plant-binarycycle[J]. Energy, 2010, 35(9): 3578-3586.
  • 8Koch C, Cziesla F, Tsatsaronis G. Optimization of combined cycle powerplants using evolutionary algorithms [J], Chemical Engineering andProcessing: Process Intensification, 2007, 46(11): 1151-1159.
  • 9吴治坚,龚宇烈,马伟斌,邓帅.闪蒸一双工质循环联合地热发电系统研究[J].太阳能学报,2009,30(3):316-321. 被引量:18
  • 10吴治坚.新能源和可再生能源的利用[M].北京:机械工业出版社,2007.

二级参考文献4

  • 1Moshe Taghaddosi. Thermodynamic modeling for combined ORC (Organic Rankine Cycle) and single-flash geothermal power plants [ A]. Proceedings World Geothermal Congress [ C], Antalya, Turkey, April 24-29, 2005.
  • 2庞麓鸣,汪孟砾,冯海仙.工程热力学[M].北京:人民教育出版社,1982.
  • 3Chmidt E,Grigull U(著),赵兆颐(译).国际单位制的水和水蒸汽性质[M].北京:水利电力出版社,1983.
  • 4丁国良 张春路.制冷空调新工质[M].上海:上海交通大学出版社,2003..