期刊文献+

短路电流非周期分量对船用发电机瞬时保护的影响及对策

Effect of Non-Periodic Component in Short Circuit Current on Shipboard Generator Instantaneous Protection and Its Countermeasures
下载PDF
导出
摘要 阐明了船用发电机保护用电磁式脱扣器与智能型脱扣器的工作原理。解释了短路电流非周期分量对电磁式脱扣器和智能型脱扣器产生影响的原因。提出了电磁式瞬时保护和智能型瞬时保护克服非周期分量影响的对策。 The work principles of electromagnetic and intelligent release controls used in shipboard generator protection were clarified. The reasons were explained that non-periodic components in short circuit current have influence on electromagnetic and intelligent release controls. At last, the countermeasures were put forward that electromagnetic and intelligent instantaneous protections overcome the influence of non-periodic component in short circuit current.
出处 《低压电器》 2013年第7期7-9,共3页 Low Voltage Apparatus
基金 上海市科技人才计划项目资助(11QB1401900)
关键词 短路电流 非周期分量 船用发电机保护 瞬时保护 short circuit current non-periodic component shipboard generator protection instantaneous protection