期刊文献+

万古霉素室间质量控制结果的评价

Evaluation of the external quality control for vancomycin
下载PDF
导出
摘要 目的评价复旦大学附属华山医院抗生素研究所,卫生部抗生素临床药理重点实验室万古霉素血药浓度监测的室间质量控制水平。方法对1984—2011年该实验室参加英国国家外部质量评价体系(UK NEQAS)的万古霉素室间质量控制数据进行回顾性分析。结果该实验室的万古霉素质控样本的自测结果与其目标浓度有良好的相关性,万古霉素自测值=0.953 1×(万古霉素目标值)+0.475 7,R2=0.966 6;且自测值与目标值的偏差均在±30%之内。结论该实验室的万古霉素室间质量控制水平良好,可进行万古霉素的常规血药浓度监测。 Objective To evaluate the level of the external quality control of Institute of Antibiotics, Huasban Hospital, Fudan University, Key Laboratory of Clinical Pharmacology of Antibiotics, Ministry of Health, in terms of therapeutic drug monitoring of vaneomycin. Methods Data of external quality assessment samples from the United Kingdom National External Quality Assessment Scheme from 1984 to 2011 were analyzed retrospectively. Results The observed level of vancomycin in our lab had a good linear correlation with its target value: observed value = 0. 953 1 × (target value) + 0. 475 7, R^2 = 0. 966 6. The observed value of vancomycin was generally within its target value ± 30%. Conclusions The lab could conduct routine therapeutic drug monitoring for vancomycin with good quality evidenced by external quality assessment.
出处 《中国感染与化疗杂志》 CAS 北大核心 2013年第3期173-175,共3页 Chinese Journal of Infection and Chemotherapy
基金 "抗耐药病原菌感染等新药临床评价研究技术平台建设"专项基金(2012ZX09303004)
关键词 万古霉素 血药浓度监测 室间质量控制 vancomycin therapeutic drug monitoring external quality assessment
  • 相关文献

参考文献7

  • 1Schilling A, Neuner E, Rehm SJ. Vancomycin: a 50-some thing-year-old antibiotic we still don't understand[J]. Cleve Clin J Med, 2011, 78(7): 465-471.
  • 2汪复,张婴元.实用抗感染治疗学[M],2版.北京:人民卫生出版社,2012: 591-594.
  • 3Rybak M, Lomaestro B, Rotschafer JC, et al. Therapeutic monitoring of vancomycin in adult patients: a consensus review of the American Society of Health-System Pharmacists, the Infectious Diseases Society of America, and the Society of Infectious Diseases Pharmacists [J]. Am J Health Syst Pharm, 2009, 66(1),82-98.
  • 4White LO. UK NEQAS in antibiotic assays[J]. J Ciin Pathol, 2000, 53(11): 829-834.
  • 5UK NEQAS for Antibiotic Assays, Manual for participants 2012 v10 (April) [EB/OL]. http://www. ukneqasaa, winuk. net/Participants Manual 2012 v10.0, htm.
  • 6Wilson JF, Davis AC, Tobin CM. Evaluation of commercial assays for vancomycin and aminoglycosides in serum: a comparison of accuracy and precision based on external quality assessment[J]. J Antimicrob Chemother, 2003, 52 ( 1 ) : 78-82.
  • 7Pfaller MA, Krogstad DJ, Granich GG, et al. Laboratory e valuation of five assay methods for vancomycin: bioassay, high-pressure liquid chromatography, fluorescence polarization immunoassay, radioimmunoassay, and fluorescence immunoassay[J]. J Clin Microbiol, 1984, 20(3):311-316.

共引文献22

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部