全桥移相软开关的开关管损耗仿真及改善

Simulating and Improving of Switch Devices Loss based on Full- Bridge Phase-Shifted Soft-Switching
下载PDF
导出
摘要 采用全桥移相软开关技术,系统地设计了一套高频直流开关电源,介绍了软启动电路、全桥逆变电路、可饱和电感、高频变压器。采用仿真研究的方法,计算了开关管的损耗,并优选开关管并联电容等参数。研究结果表明,采用软开关技术更有利于发展大功率直流电源。 A high frequency DC switching power supply is systematically designed based on the full- bridge phase-shifted soft-switching technology. Soft starting circuit, full bridge inverter, saturable inductor, high frequency transformer are described. The energy loss of switch tubes are estimated and parameters of parallel capacitor of switches are selected. It shows that the soft-switching technology is favorable for development of high-power DC power supply.
出处 《电源技术应用》 2013年第6期57-61,共5页 Power Supply Technologles and Applications
关键词 软开关 全桥移相 可饱和电感 高频变压器 so.switching full-bridge phase-shifted saturable inductor high frequency transformer
  • 相关文献

参考文献6

二级参考文献9

  • 1梁志刚,吴燮华.ZVS-FB变换器辅助谐振网络作用范围研究[J].电力电子技术,2006,40(1):36-38. 被引量:3
  • 2阮新波.移相控制零电压开关PWM变换器的研究:(博士学位论文)[M].南京航空航天大学,1996..
  • 3王建冈.改进型倍流整流电路ZVS PWM全桥变换器的研究:(硕士学位论文)[M].南京航空航天大学,2000..
  • 4José R Rodriguez,Jorge Pontt,et al.Large Current Rectifiers:State of the Art and Future Trends[J].IEEE Trans.ON Industrial Electronics,2005,3,(52):738-746.
  • 5Scaini V,Ma T.High current DC Choppers in the Metals Industry[J].IEEE Industry Application Conference,2000,(4):2629-2636.
  • 6Scaini V,Urban B M.High current DC Choppers and their operational benefits[C].Petroleum and Chemical Industry Conference.1998:173-180.
  • 7ABB Group.http://www.abb.com
  • 8戴鹏,左东升,乔树通.SIMADYN D在可控硅电解装置中的应用[C].2003全国电解整流技术应用研讨会.
  • 9吕照瑞,张俊洪,赵镜红.全桥PWMZVZCS变换器电路的分析设计[J].电力电子技术,2003,37(5):36-38. 被引量:9

共引文献24

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部