摘要 对于安全要求高的电力驱动系统,其电机应具有容错性能。为提高永磁容错电机在系统正常工作时的控制性能,在分析其结构特点的基础上,建立起电机在旋转坐标系下的数学模型,并实现电流、磁链、转矩的解耦控制。通过观察磁链、转矩、转速和电流波形,验证了控制策略的可行性和有效性。 The motor drive should have the function of fault tolerance in case that a critical safety was inquired in the electric driving system. In order to improve the control performance of the fault-tolerant permanent magnet motor in the normal operation, the mathematical model of the motor was established in the rotating coordinate system based on the analysis of its structural features, as well as the decoupling control of current, flux and torque was realized. Trough observation on the waveforms of flux, torque, speed and current, the feasibility and effectiveness of control strategies were verified.
出处 《电机技术》 2013年第2期23-27,共5页 Electrical Machinery Technology
关键词 永磁容错电机 直接转矩控制Matlab SIMULINK Fault-tolerant permanent magnet motor Direct torque control Matlab/Simulink
  • 相关文献

参考文献5

二级参考文献13

  • 1Takahashi I ,Noguchi T. A new quick-response and high-efficiency control strategy of an induction motor [ J ]. IEEE Trans on Industrial Applications, 1986,22 (5) :821 - 827.
  • 2Zhong L,Rahman M F. Analysis of direct torque control in permanent magnet drives [ J ]. IEEE Transactions on Power Electronics, 1997,12 ( 3 ) :528 - 535.
  • 3Mecrow B C, Atkinson D J, Jack A G, et al. The Need for Fault Tolerance in an Aeroengine Electric Fuel Control System. Electrical Machines and Systems for the More Electric Aircraft, IEE Colloquium, 1999.
  • 4Mccrow B C, Jack A G, Atkinson D J, Haylock J A. Fault Tolerant Drives for Safety Critical Applications. New Topologies for Permanent Magnet Machines, IEE Colloquium, 1997.
  • 5Yu-Seok Jeong, Seung-Ki Sul, Schulz S, Patel N. Fault Detection and Fault Tolerant Control of Interior Permanent Magnet Motor Drive System for Electric Vehicle. Industry Applications Conference, 2003, 3(12): 1458~1463.
  • 6Mecrow B C, Jack A G, Haylock J A, Coles J. Fault-Tolerant Permanent MagnetMachine Drives. Proceedings of IEE on Electric Power Conference, 1996, 143(6): 437~442.
  • 7Green S, Atkinson D J, Mecrow B C, Ack A G,Green B. Fault Tolerant, Variable Frequency, Unity Power Factor Converters for Safety Critical PM Drives. Proceedings of IEE on Electric Power Applications, 2003, 150(6): 663~672.
  • 8Atallah K, Caparrelli F, Bingham C M, et al. Comparison of Electrical Drive Technologies for Aircraft Flight Control Surface Actuation. Proceedings of the Ninth International Conference Electrical Machines and Drives, 1999, 159~163.
  • 9Mecrow B C,Jack A G,Atkinson D J, et al. Design and Testing of a 4 Phase Fault Tolerant Permanent Magnet Mach-ine for an Engine Fuel Pump. Proceedings of IEEE International Conference on Electric Machines and Drives, 2003, 2(1): 1301~1307.
  • 10Ertugrul N, Soong W L,Valtenbergs S,Chye H. Investigation of a Fault Tolerant and High Performance Motor Drive for Critical Applications. Proceedings of IEEE Region International Conference on Electrical and Electronic Technology, 2001, 19(2): 542~548.

共引文献64

同被引文献27

  • 1齐蓉,陈明.多电飞机容错作动系统拓扑结构分析[J].航空计算技术,2005,35(1):82-85. 被引量:4
  • 2Boglietti A, Cavagnino A, The Safety Critical Electric Tenconi A, Vaschetto et al. Machines and Drives in the More Electric Aircraft : a Survey [ C ]. IIECON' 09. 35th Annum Conference of IEEE, 2009 : 2587-2594.
  • 3Jack A G,Mecrow B C,Haylock J. A Comparative study of permanent magnet and switched reluctance motors for high-performance fauh-tolerant applications [J]. IEEE Transitions on industry Applications, 1996,32 (4) : 889- 895.
  • 4Mecrow B C,Jaek A G,Hayloek J A.Fault tolerant per- manent magnet machine drives [J ]. IEE Proceedings of Electrical Power Applications, 1996,143 (6) :437-442.
  • 5Hayloek J A,Meerow B C,Jaek A G.Enhaneed current control of high-speed PM machine drives through the use of flux eontrollers [J].IEEE Trans. on Industry Ap- plications, 1999, 35(5): 1030-1038.
  • 6M dai, Keyhani A, Sebastian T. Torque ripple analysis ofa PM brushless DC motor using finite element method [J]. IEEE Transactions on Energy Conversion,2004,19: 40-45.
  • 7Jack, A.G. Mecrow B.C. Haylock J.A. A comparative study of permanent magnet and switched reluctance motors for high- performance fault-tolerant applications[J]. IEEE Transactions on Industry Applications, 1996, 32 (4) : 889-895.
  • 8B.C.Mecrow, A.G.Jack, J.A.Haylock, J.Coles. Fault-tolerantpermanent magnet machine drives[J]. IEE Proceedings-Elec- tric Power Applications, 1996, 143 (6) : 437-442.
  • 9J.A.Haylock, B.C.Mecrow, A.G.Jack and D.J.Atkinson. Op- eration of a fault tolerant PM drive for an aerospace fuel pump application[J], lEE Proceedings on Electric Power Applica- tions. 1998, 145 (5) : 441-448.
  • 10B.C.Mecrow, A.G.Jack, D.J.Atkinson and S.R.Oreen. Design and testing of a four-phase fault-tolerant permanent-magnet machine for an engine fuel pump[J]. IEEE Transactions on En- ergy Conversion. 2004, 19 (4) : 671-678.