摘要 隔震在民用建筑领域的应用越来越多,是减震抗灾的有效手段之一。中国核电站的厂址加速度比国外某些核电站的厂址加速度大,对于引进的核电站需要降低其地震响应。日本的地震活动比较活跃,在隔震方面的研究和应用比较多。日本在多年研究的基础上,选择了两种快堆核电站的三维隔震装置,制作缩比例模型完成振动台试验。试验结果表明两种隔震装置均适用于快堆核电站。 Seismic isolation is applied more and more in the civil architecture and it is one of the valid measurements of shock absorption and against disasters. The cites acceleration of China nuclear power plant is bigger than the foreign nuclear power plant. It is necessary to decay the nuclear power plant response. Research and apply of nuclear power plant is much because the Japan earthquake is active. Based on many year researches, the two 3-dimension base isolation devices of Fast Breeder Reactor are selected and scaling models are made and tested. Judging from the results of the shaking table test, the developed 3-D base isolation devices are applied to a nuclear power plant.
出处 《机电产品开发与创新》 2013年第3期13-14,20,共3页 Development & Innovation of Machinery & Electrical Products
关键词 核电站 隔震 nuclear power plant seismic isolation
  • 相关文献

参考文献10

  • 1Et本电气协会原子能委员会.原子力发电所免震构造设计技术指针[S].2000.
  • 2Y.Sawada, et al., Seismic Isolation Test Program, Proc. of the lOth SMiRT,1989.
  • 3M.Nakazawa, et al. Study on Seismic Base Isolation of LWR Plants, Proc., of the llth SMiRT, 1991.
  • 4Asao Kato, et al. A Development Program of 3-Dimensional Seismic Isolation for Advanced Reactor System in Japan, Proc. of the 17th SMiRT, 2003.
  • 5Seiji Kitanura, et al.Experimental Study on Coned Disk Springs for Vertical Seismic Isolation System, Proc. of the 13th SMiRT,2003.
  • 6Kenji Kanazawa,et al.Shaking Table Test of 3-Dimensional Base Isolation System Using Laminated Thick Rubber Bearings, Proc. of the 15th SMiRT,1999.
  • 7Junji Suhara, et al.Research on 3D Base Isolation System Applied to New Power Reactor 3D Seismic Isolation Device with Rolling Seal Tyoe Air Spring:Part 2, Proc. of the 18th SMiRT,2005.
  • 8Takahiro Shimada, et al. Study on 3-Dimensional Base Isolation System Applied to New Power Plant Reactor: Part 2 (Hydraulic 3- Dimensional Base-Isolation System), Proc. of the 18th SMiRT, 2005.
  • 9Shigeki Okamura, et al.Experiment Study on Vertical Component Isolation System, Proc. of the 18th SMiRT,2005.
  • 10Kenji Takahashi, et al.a Development of 3-Dimensional Seismic Isolation for Advanced Reactor Systems in Japan-Part 2, Proc. of the 18th SMiRT, 2005.