摘要
用事件树分析方法对压水堆核电厂主蒸汽管道破裂诱发的蒸汽发生器传热管断裂进行了事故序列分析 ,找出了引起堆芯裸露的支配性事故序列。结果表明 ,由主蒸汽管道破裂诱发的蒸汽发生器传热管断裂导致堆芯裸露的频率为1
The accident sequence analyses of steam generator heating surface tube rupture induced by main steam line break are presented The reactor core uncovering accident occurring frequency is 1 04×10-6/r a The dominant accident sequence resulting reactor core melt has also been identified
出处
《核动力工程》
EI
CAS
CSCD
北大核心
2000年第2期152-156,共5页
Nuclear Power Engineering
关键词
事件树
蒸汽发生器
传热管断裂
事故分析
Event tree Steam generator Heating surface tube rupture Probability safety analysis