期刊文献+

石墨炉原子吸收法测定空心胶囊中铬含量的不确定度分析 被引量:1

Uncertainty Evaluation of Determing Chromium Content in Vacant Capsules by Graphite Furnace-AAS
下载PDF
导出
摘要 目的:评定石墨炉原子吸收法测定空心胶囊中铬含量的不确定度,找出影响不确定度的主要因素。方法:根据《测量不确定度评定与表示》(JJF1059-1999)有关规定分析不确定度的来源,利用回归方程进行不确定度的评定。结果:本实验中空心胶囊中铬的含量表示为0.24±0.03mg·kg-1(包含因子k=2)。结论:石墨炉原子吸收法测定空心胶囊中铬含量时,标准曲线计算铬含量产生的不确定度对总不确定度的影响最大。 Objective The present study was conducted to evaluate the uncertainty in determination of chromium (Cr) in vacant cap-sules using graphite fumace-AAS and to find out the factors affecting the uncertainty. Methods The uncertainty source was analyzed and regression equation was applied for uncertainty evaluation according to JJF1059-1999. Results The content of Cr in vacant capsules was ,and the expanded uncertainty was (k=2). Conclusion When the Cr content in vacant capsules was determined using graphite fur-nace-AAS, the uncertainty encountered in calculating Cr content using standard curve showed significant effects on Cr determination.
出处 《黑龙江医药》 CAS 2013年第3期348-350,共3页 Heilongjiang Medicine journal
关键词 石墨炉原子吸收法 空心胶囊 不确定度 Graphite furnace-AAS Vacant capsules Chromium Uncertainty
  • 相关文献

参考文献2

  • 1中国药学会译.日本药学会编著卫生试验法[M].北京;华文出版社.1995.57.
  • 2国家质量技术监督局.中华人民共和国国家计量技术规范JJF1059-1999.测量不确定度法评定与表示[s].北京:中国计量出版社,1999.

同被引文献18

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部