摘要 主动脉瓣人工瓣膜一患者不匹配(Prosthesis—patien tmismatch,PPM)是主动脉瓣置换术后的常见现象,目前尚无一种既简单快捷又客观准确的参数可以方便地评价PPM。PPM的临床意义仍有争议,为避免PPM的发生,可以考虑植入更好血流动力学表现的人工瓣膜或行主动脉根部扩大术、根部替换术,但应仔细权衡由此带来的风险与获益比。
出处 《中国医药》 2013年第6期869-870,共2页 China Medicine
  • 相关文献

参考文献15

  • 1Rahimtoola SH. The problem of valve prosthesis-patient mismatch.Circulation, 1978,58(1):20-24.
  • 2Cotoni DA, Palac RT, Dacey LJ, et al. Defining patient-prosthesismismatch and its effect on survival in patients with impaired ejec-tion fraction. Ann Thorac Surg, 2011,91 (3) :692-699.
  • 3Duraesnil JG, Honos GN, Lemieux M, et al. Validation and appli-cations of indexed aortic prosthetic valve areas calculated byDoppler echocardiography. J Am Coll Cardiol, 1990,16(3) :637-643.
  • 4Florath I, Albert A, Rosendahl U, et al. Impact of valve prosthe-sis-patient mismatch estimated by echocardiographic-determined ef-fective orifice area onlong-term outcome after aortic valve replace-ment. Am Heart J, 2008,155(6):1135-1142.
  • 5Pibarot P, Duraesnil JG. Prosthesis-patient mismatch: definition,clinical impact, and prevention. Heart, 2006,92(8) : 1022-1029.
  • 6Kukucka M, Pasic M, Dreysse S, et al. Patient-prosthesis mis-match after transapical aortic valve implantation : incidence andim-pact on survival. J Thorac Cardiovasc Surg, 2013 , 145(2) :391-397.
  • 7Mohty D, Dumesnil JG, Echahidi N, et al. Impact of prosthesis-patient mismatch on long-term survival after aortic valve replace-ment: influence of age, obesity, and left ventricular dysfunction. JAm Coll Cardiol, 2009,53(1) :3947.
  • 8Price J, Lapierre H, Ressler L, et al. Prosthesis-patient mismatchis less frequent and more clinically indolent in patients operated foraorticinsufficiency. J Thorac Cardiovasc Surg, 2009,138( 3 ) :639-645.
  • 9Garcia D,Camici PG, Durand LG, et al. Impairment of coronaryflow reserve in aortic stenosis. J Appl Physiol, 2009,106( 1) : 113-121.
  • 10Blais C, Dumesnil JG, Baillot R, et al. Impact of valve prosthesis-patient mismatch on short-term mortality after aortic valve replace-ment. Circulation, 2003 ,108(8) :983-988.

同被引文献22

  • 1Pibarot P, Dumesnil J (9. Valve prosthesis patient mismatch, 1978 to 2011 : from original concept to compelling evidence[J]. J Am Coll Cardiol,2012,60(13) : 1136-- 1139.
  • 2Rahimtoola S H. The problem of valve prosthesis patient mismatch [J]. Circulation, 1978,58 (1) : 20-- 24.
  • 3Impact of valve prosthesis patient mismatch on short term mortality after aortic valve replace ment[J]. Circulation, 2003,108(8) : 983 988.
  • 4Walther T,Rastan A,Falk V,et al. Patient prosthesis mismatch af- fects short and long-term outcomes after aortic valve replacement [J]. Eur J Cardiothorac Surg,2006,30(l) :15-- 19.
  • 5Jamieson W R, Ye J, Higgins J,et al. Effect of prosthesis-patentmismatch on long-term survival with aortic valve replacement: as- sessment to 15 years[J]. Ann Thorac Surg,2010,89(1) :51--58.
  • 6Pibarot P,Dumesnil J G. Live longer and better without prosthesis-pa tient mismatch[J]. J Heart Valve Dis,2009,18(3) :24,5 247.
  • 7Kohsaka S, Mohan S,Viranis S, et aL Prosthesis-patiem mismatch affects survival after aortic valve replaeement[J]. J Thorac Cardio- vasc Surg,2008,135(5) :1076--1080.
  • 8Howell N J, Keogh g E, garnet V, et al. Patient prosthesis-mis match does no* affect survival following aortic valve replacement [J]. Eur J Cardiothorac Surg,2006,30(1) :10-- 14.
  • 9Pibarot P, Dumesnil J G. Hemodynamic and clinical impact of pros thesis-patient mismatch in the aortic valve position and its preven lion [J]. J Am Coil Cardiol,2000,36(4) 1131-- 1141.
  • 10Melina G, Angeloni E, Benedetto U, et al. Relationship between prosthesis-patient mismatch and pro-brain natriuretic peptides after aortic valvereplacement[J]. J Heart Valve Dis, 2010, 19(2): 171-176.