期刊文献+

学龄前儿童电脑验光和检影验光的对比研究 被引量:4

A comparative study of computer optometry and retinoscopy optometry in preschooler children
下载PDF
导出
摘要 目的:比较电脑验光和检影验光在学龄前儿童客观屈光检查中的应用价值。方法:门诊屈光不正的学龄前儿童98例196眼,年龄3~6岁,使用10g/L阿托品眼膏涂眼,2次/d,连用4d,第5d停药后分别使用电脑验光和检影验光,结果进行统计学分析比较。结果:比较电脑验光和检影验光的结果显示远视球镜均值电脑验光法(2.70±2.75D)所测结果低于检影验光法(2.99±2.09D),行配对t检验,两种方法结果比较差异有统计学意义(P<0.05);近视球镜均值电脑验光法(-2.74±1.25D)所测结果高于检影验光法(-2.35±2.18D),结果比较差异有统计学意义(P<0.05);散光轴向两种方法比较差异无统计学意义(P>0.05),而散光度数值均值比较差异有统计学意义(P<0.05)。结论:电脑验光和检影验光法在学龄前儿童散瞳验光应用中各有利弊,临床工作中需结合使用。 AIM- To estimate the value of application computer optometry and retinoscopy optometry for objective refraction test in preschooler children. METHODS: Ninety- eight preschooler children aged from 3 to 6 years old (196 eyes) of out-patient with abnormal refraction were chosen at random and examined. 10g/L atropine eye ointment was applied twice a day for four days. The fifth day, computer optometry and retinoscopy optometry were used separately. The results of optometry were analyzed statistically. RESULTS: A comparison of the computer optometry and retinoscopy optometry results showed that: Forhyperopic refraction, the mean spherical equivalent refractions of computer optometry (2.70±2.75D) was less positive values than that of retinoscopy optometry (2.99± 2.09 D). A matched-pairs t-test showed that there was a significant difference ( P〈 0.05). For myopic refraction, the mean spherical equivalent refractions of computer optometry (-2.74±1.25D) was more negative values than that of retinoscopy (- 2. 35 ±2. 18D). There was a significant difference (P〈0.05). There was no significant difference in the position of astigmatic axis between two methods of measurement (P〉0.05). With regard to the astigmatism degree, there existed significant difference between the computer optometry and retinoscopy optometry results (P〈0.05). CONCLUSION:Computer optometry and retinoscopy optometry had their own merits and defects in measurement of objective refraction in preschoolerchildren. They should complement each other to provide accurate evidence for vision correction in clinical work.
出处 《国际眼科杂志》 CAS 2013年第6期1297-1298,共2页 International Eye Science
关键词 学龄前儿童 散瞳 电脑验光 检影验光 阿托品 preschoolers mydriasis computeroptometry retinoscopy optometry atropine
  • 相关文献

参考文献10

二级参考文献65

共引文献33

同被引文献40

引证文献4

二级引证文献15

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部