期刊文献+

Effects of zinc-substituted nano-hydroxyapatite coatings on bone integration with implant surfaces 被引量:7

Effects of zinc-substituted nano-hydroxyapatite coatings on bone integration with implant surfaces
原文传递
导出
摘要 Objective:The purpose of this study was to investigate the effects of a zinc-substituted nano-hydroxyapatite(Zn-HA) coating,applied by an electrochemical process,on implant osseointegraton in a rabbit model.Methods:A Zn-HA coating or an HA coating was deposited using an electrochemical process.Surface morphology was examined using field-emission scanning electron microscopy.The crystal structure and chemical composition of the coatings were examined using an X-ray diffractometer(XRD) and Fourier transform infrared spectroscopy(FTIR).A total of 78 implants were inserted into femurs and tibias of rabbits.After two,four,and eight weeks,femurs and tibias were retrieved and prepared for histomorphometric evaluation and removal torque(RTQ) tests.Results:Rod-like HA crystals appeared on both implant surfaces.The dimensions of the Zn-HA crystals seemed to be smaller than those of HA.XRD patterns showed that the peaks of both coatings matched well with standard HA patterns.FTIR spectra showed that both coatings consisted of HA crystals.The Zn-HA coating significantly improved the bone area within all threads after four and eight weeks(P<0.05),the bone to implant contact(BIC) at four weeks(P<0.05),and RTQ values after four and eight weeks(P<0.05).Conclusions:The study showed that an electrochemically deposited Zn-HA coating has potential for improving bone integration with an implant surface. Objective:The purpose of this study was to investigate the effects of a zinc-substituted nano-hydroxyapatite(Zn-HA) coating,applied by an electrochemical process,on implant osseointegraton in a rabbit model.Methods:A Zn-HA coating or an HA coating was deposited using an electrochemical process.Surface morphology was examined using field-emission scanning electron microscopy.The crystal structure and chemical composition of the coatings were examined using an X-ray diffractometer(XRD) and Fourier transform infrared spectroscopy(FTIR).A total of 78 implants were inserted into femurs and tibias of rabbits.After two,four,and eight weeks,femurs and tibias were retrieved and prepared for histomorphometric evaluation and removal torque(RTQ) tests.Results:Rod-like HA crystals appeared on both implant surfaces.The dimensions of the Zn-HA crystals seemed to be smaller than those of HA.XRD patterns showed that the peaks of both coatings matched well with standard HA patterns.FTIR spectra showed that both coatings consisted of HA crystals.The Zn-HA coating significantly improved the bone area within all threads after four and eight weeks(P〈0.05),the bone to implant contact(BIC) at four weeks(P〈0.05),and RTQ values after four and eight weeks(P〈0.05).Conclusions:The study showed that an electrochemically deposited Zn-HA coating has potential for improving bone integration with an implant surface.
出处 《Journal of Zhejiang University-Science B(Biomedicine & Biotechnology)》 SCIE CAS CSCD 2013年第6期518-525,共8页 浙江大学学报(英文版)B辑(生物医学与生物技术)
基金 Project supported by the National Natural Science Foundation of China (No. 81000462) the Zhejiang Provincial Natural Science Foundation (No. R2110374),China
关键词 ZINC Hydroxyapatite coating Electrochemical process OSSEOINTEGRATION IMPLANT Zinc; Hydroxyapatite coating; Electrochemical process; Osseointegration; Implant
  • 相关文献

参考文献34

  • 1Alvarez, K., Fukuda, M., Yamamoto, O., 2010. Titanium implants after alkali heating treatment with a [Zn(OH)4]2 complex: analysis of interfacial bond strength using push-out tests. Clin. Implant Dent. Relat, Res., 12(sl): el 14-e125. [doi:lO.1111/j.1708-8208.2010.OO278.x].
  • 2Angus, R.M., Sambrook, P.N., Pocock, N.A., Eisman, J.A., 1988. Dietary intake and bone mineral density. Bone Miner.. 4(3:265-277.
  • 3Barceloux, D.G., 1999. Zinc. Clin. Toxieol., 37(2):279-292. [doi:10.1081/CLT-100102426].
  • 4Davies, J.E., 1998. Mechanisms ofendosseous integration. Int. J. Prosthodont., 11(5):391-401.
  • 5Davies, J.E., 2000. Understanding peri-implant endosseous healing. J. Dent. Educ., 67(8):932-949.
  • 6Ellies, L.G., Nelson, D.G., Featherstone, J.D., 1992. Crystallographic changes in calcium phosphates during plasma-spraying. Biomaterials, 13(5):313-316. [doi:10. 101610142-9612(92)90055-S].
  • 7Guo, X., Gough, J.E., Xiao, P., Liu, J., Shen, Z., 2007. Fabrication of nanostructured hydroxyapatite and analysis of human osteoblastic cellular response. J. Biomed. Mater. Res. A, 82(4):1022-1032. [doi:10.1002/ jbm.a.31200].
  • 8Hall, S.L., Dimai, H.P., Farley, J.R., 1999. Effects of zinc on human skeletal alkaline phosphatase activity in vitro. Calcif Tissue Int., 64(2):163-172. [doi:10.1007/s0022 399005971.
  • 9Hatakeyama, D., Kozawa, O., Otsuka, T., Shibata, T., Uematsu, T., 2002. Zinc suppresses IL-6 synthesis by prostaglandin F2 in osteoblasts: inhibition of phospholipase C and phospholipase D. J. Cell. Biochem., 85(3):621-628. [doi:10.1002/jcb.10166].
  • 10He, F.M., Yang, G.L., Wang, X.X., Zhao, S.F., 2009. Effect of electrochemically deposited nano-hydroxyapatite on bone-bonding of sandblasted-dual acid etched titanium implant. Int. J. Oral Maxillofac. Implants', 24(5):790-799.

同被引文献41

引证文献7

二级引证文献12

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史