摘要 针对电力系统实时相位跟踪问题,提出了基于自适应记忆长度的最小二乘参数估计方法。该方法直接观测三相电网电压矢量角度,并将电压相位角分解分成基波相角和由谐波或不平衡引起的相角偏离两部分,并以电网基波初相位角和角频率为参数来建立观测方程。以整周期相位误差平方和最小为目标函数,采用自适应记忆长度递推最小二乘法进行实时参数估计。试验结果表明,在各种电网畸变情况下,该方法都表现出良好的实时相位跟踪特性。 In allusion to realtime tracking of system frequency and phase, a least square parameter estimation method based on adaptive memory length is proposed. This method directly observe the angle of voltage vector in three-phase power network, and the phase angle of voltage is decomposed into phase angle of fundamental component and phase angle deviation due to harmonics or system unbalance, and taking initial phase angle and angular frequency of fundamental component as parameters a observation equation is established. Taking quadratic sum of phase error in a full period as objective function, the realtime parameters are estimated by recursive least square method based on adaptive memory length. There is no trigonometric calculation in iterative process of the algorithm. The results of experiments show that the algorithm is of good tracking performance under kinds of distorted utility conditions.
出处 《电网技术》 EI CSCD 北大核心 2013年第6期1753-1758,共6页 Power System Technology
基金 国家电网公司科技项目(PD17201200044)~~
关键词 自适应记忆长度 最小二乘法 参数估计 实时相位检测 adaptive memory length least square method parameter estimation real-time phase measurement
  • 相关文献

参考文献19

二级参考文献62

共引文献283

同被引文献65

  • 1孔雪娟,罗昉,彭力,康勇.基于周期控制的逆变器全数字锁相环的实现和参数设计[J].中国电机工程学报,2007,27(1):60-64. 被引量:45
  • 2卢秋波.视频监控技术简介与发展趋势[J].电信网技术,2007(1):9-12. 被引量:15
  • 3彭谦,杨以涵.基于导纳修正的配电网状态估计方法[J].电网技术,2007,31(8):83-86. 被引量:3
  • 4HAYKIN S.自适应滤波器原理[M].北京:电子工业出版社,2003.
  • 5禹永植,张忠民,席志红.基于傅里叶变换的高精度频率及相量算法[J].电网技术,2007,31(23):83-86. 被引量:16
  • 6RODRIGUEZ P, LUNA A, CANDELA I, et al. Multi- resonant frequency-locked loop for grid synchronization of power converters unde.r distorted grid conditions [ J ]. IEEE Transaction on Industrial Electronics, 2011, 58(1) :127-137.
  • 7DE ARAUJO RIBEIRO R L, DE AZEVEDO C C, DE SOUSA R M. A robust adaptive control strategy of active power filter for power-factor correction, harmonic com- pensation, and balancing of nonlinear loads [ J ]. IEEE Transaction on Power Electronics, 2012, 27 ( 2 ) : 718-730.
  • 8DU S, LIU J, LIN J, et al. A novel DC voltage control method for STATCOM based on hybrid multilevel H-bridge converter[ J]. IEEE Transaction on Power Elec- tronics, 2013, 28(1):101-111.
  • 9MOHAMED Y A R I, EL-SAADANY E F. A robust natural frame based inter facing scheme for grid-con- nected distributed generation inverters[ J]. IEEE Trans- action on Energy Conversion, 2011, 26(8 ):728-736.
  • 10XIA Y L, DOUGLAS S C, MANDIC D P. Adaptive fre- quency estimation in smart grid applications: Exploiting noncircularity and widely linear adaptive estimators [ J ]. IEEE Signal Processing Magazine, 2012, 29(5) :44-54.