摘要
本文介绍了中国实验快堆(CEFR)核发热开始点测量试验的测量方法、试验过程及试验结果,给出了主泵转速为150r/min的核发热开始点数据,为后续低功率试验提供参考。
The experiment of the zero power level measurement on China Experimental Fast Reactor(CEFR) was introduced in this paper.The results of 150 r/min main pump speed were shown.The data are the important reference for the following experiment in the low-power stage.
出处
《原子能科学技术》
EI
CAS
CSCD
北大核心
2013年第B06期95-98,共4页
Atomic Energy Science and Technology
关键词
中国实验快堆
核发热开始点
低功率试验
China Experimental Fast Reactor
nuclear power heating starting point
low-power experiment