摘要 Air pollution surveys of formaldehyde(HCHO) were conducted in 2324 rooms decorated within one year in 2007-2009 in Hangzhou,China.The mean HCHO concentration(C HCHO) was 0.107 ± 0.095 mg/m 3,and 38.9% of samples exceeded the Chinese National Standard GB 50325-2010.Over the past 3 years,the C HCHO decreased with time(p 〈 0.05).Relationships of potential factors to indoor C HCHO were also evaluated.C HCHO was related to temperature(T),relative humidity(RH),time duration of the windows and doors being closed before sampling(DC),time duration from the end of decoration to sampling(DR) and source characteristics(d).A model to relate indoor C HCHO to these five factors(T,RH,DC,DR,d) was established based on 298 samples(R 2 = 0.87).Various factors contributed to C HCHO in the following order:T,43.7%;d,31.0%;DC,10.2%;DR,8.0%;RH,7.0%;specifically,meteorological conditions(i.e.,RH plus T) accounted for 50.7%.The coefficient of T and RH,R TH,was proposed to describe their combined influence on HCHO emission,which also had a linear relationship(R 2 = 0.9387) with HCHO release in a simulation chamber test.In addition,experiments confirm that it is a synergistic action as T and RH accelerate the release of HCHO,and that is a significant factor influencing indoor HCHO pollution.These achievements could lead to reference values of measures for the efficient reduction of indoor HCHO pollution. Air pollution surveys of formaldehyde(HCHO) were conducted in 2324 rooms decorated within one year in 2007-2009 in Hangzhou,China.The mean HCHO concentration(C HCHO) was 0.107 ± 0.095 mg/m 3,and 38.9% of samples exceeded the Chinese National Standard GB 50325-2010.Over the past 3 years,the C HCHO decreased with time(p 〈 0.05).Relationships of potential factors to indoor C HCHO were also evaluated.C HCHO was related to temperature(T),relative humidity(RH),time duration of the windows and doors being closed before sampling(DC),time duration from the end of decoration to sampling(DR) and source characteristics(d).A model to relate indoor C HCHO to these five factors(T,RH,DC,DR,d) was established based on 298 samples(R 2 = 0.87).Various factors contributed to C HCHO in the following order:T,43.7%;d,31.0%;DC,10.2%;DR,8.0%;RH,7.0%;specifically,meteorological conditions(i.e.,RH plus T) accounted for 50.7%.The coefficient of T and RH,R TH,was proposed to describe their combined influence on HCHO emission,which also had a linear relationship(R 2 = 0.9387) with HCHO release in a simulation chamber test.In addition,experiments confirm that it is a synergistic action as T and RH accelerate the release of HCHO,and that is a significant factor influencing indoor HCHO pollution.These achievements could lead to reference values of measures for the efficient reduction of indoor HCHO pollution.
出处 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2013年第5期908-915,共8页 环境科学学报(英文版)
基金 supported by the National Natural Science Foundation of China (No. 20890111,21137003,20977075) the National High-Tech Research and Development Program (863) of China (No. 2010AA064902)
关键词 FORMALDEHYDE indoor air quality EMISSION factor analysis TEMPERATURE relative humidity formaldehyde indoor air quality emission factor analysis temperature relative humidity
  • 相关文献

参考文献2

二级参考文献93

  • 1Brown S K. Volatile organic pollutants in new and established buildings in Melbourne, Australia. Indoor Air, 2002, 12:55-63.
  • 2Andersson K, Bakke J V, Bjorseth O, et al. TVOC and health in non-industrial indoor environments - Report from a Nordic scientific consensus meeting at Langholmen in Stockholm. Indoor Air, 1997, 7: 78-91.
  • 3Molhave L,Clausen G, Berglund B, et al. Total volatile organic compounds (TVOC) in indoor air quality investigations. Indoor Air, 1997, 7:225-240.
  • 4Tian Y C, Sun Y B, Ping J W, et al. SO2, HCHO, and TVOCs pollution in living rooms of Nanjing. Acta Sci Circums, 2007, 27:190-194.
  • 5Jarnstrom H, Saarela K, Kalliokoski P, et al. Reference values for indoor air pollutant concentrations in new, residential buildings in Finland. Atmos Environ, 2006, 40:7178-7191.
  • 6Haghighat F, Bellis De L. Material emission rates: Literature review, and the impact of indoor air temperature and relative humidity. Build Environ, 1998, 33:261-277.
  • 7Zhang Q, Zhang G Q. Study on TVOCs concentration distribution and evaluation of inhaled air quality under a re-circulated ventilation system. Build Environ, 2007, 42:1110-1118.
  • 8Yan W, Zhang Y P, Wang X K. Simulation of VOC emissions from building materials by using the state-space method. Build Environ, 2009, 44:471-478.
  • 9Ministry of Construction of the People's Republic of China. GB 50325-2001 Code for indoor environmental pollution control of civil building engineering (2006). Beijing: China Planning Press, 2006.
  • 10Jokl M V. Evaluation of indoor air quality using the decibel concept based on carbon dioxide and TVOC. Build Environ, 2000, 35:677-697.