期刊文献+

高强钢筋混凝土结构设计及工程实例中钢筋用量分析 被引量:3

Design of concrete structures with high strength reinforcement and analysis of the reinforcement amount in engineering projects
原文传递
导出
摘要 讨论高强钢筋混凝土结构设计中的钢筋锚固长度和裂缝宽度控制等问题,对3个工程实例分别采用500,400,335MPa级热轧带肋钢筋进行设计,对不同强度等级钢筋的用量进行了分析和比较,得出了用400MPa级钢筋代替335MPa级钢筋用量可减少约10%、用500MPa级钢筋代替335MPa级钢筋用量可减少约20%的结论,并提出了高强钢筋工程设计和应用的建议。 The anchorage length and the control of crack width in reinforced concrete structures with high strength reinforcement were discussed.For 3 engineering projects,hot-rolled ribbed steel bars of 500MPa,400MPa and 335MPa grade were used respectively.The reinforcement amount of different strength were analyzed and compared.The results show that the reinforcement amount may decrease about 10% for using reinforcement of 400MPa instead of steel bars of 335MPa.When using 500MPa grade steel bars to replace the 350MPa ones,the reduction can be 20%.According to the results,suggestions for the design and application of the high strength reinforcement in engineering were also given.
出处 《建筑结构》 CSCD 北大核心 2013年第10期59-63,30,共6页 Building Structure
基金 国家科技支撑计划项目(2008BAE61B04)
关键词 高强钢筋 钢筋用量 锚固长度 裂缝宽度 high strength reinforcement reinforcement amount anchorage length crack width
  • 相关文献

参考文献3

  • 1刘立新,杜朝华.500MPa级钢筋混凝土柱受压性能试验研究[J].公路交通科技(应用技术版),2011,7(10):241-245. 被引量:7
  • 2RISN-TG007-2009热轧带肋高强钢筋在混凝土结构中应用技术导则[S].北京:中国建筑工业出版社,2010.
  • 3GB50010-2010混凝土结构设计规范[S].北京:中国建筑工程出版社,2011.

二级参考文献1

共引文献264

同被引文献10

引证文献3

二级引证文献4