摘要 以嵌入式ARM9控制器和FPGA为处理核心,设计了手持式的电压波动与闪变测试仪,可以同时测量4路交流电压信号的短时闪变值Pst和长时闪变值Plt。为了简化运算过程,对电压每半周波进行一次方均根值运算,并对得到的方均根值序列进行快速傅里叶变换,求解出各频率下对应的瞬时闪变值,并利用概率大值法求解短时闪变。通过在FPGA中的2组存储器交替接收数据,利用乒乓方式实现32位的FFT算法,可大幅提高运算速度与精度。实验结果表明,本测试仪对于方均根值计算精度达到2‰,闪变测量精度达到2%。 The handheld voltage fluctuation and flicker meter based on ARM9 and FPGA is introduced. The meter can measure 4 channels AC voltage signals at thesame time,and the short term severity Pst and long term severity Pit can be calculated. In order to simplify the operation process, the root-mean-square value of each half wave is calculated and a series of RMS value is got. The instantaneous flicker value of each corresponding frequency can be got by the FFT operation to the RMS sequences,and the short term severity Pst is calculated by the method of max probability value. Through the two group of memory in the FPGA alternately receiving data, the 32-bits FFT algorithm using the pingpong mode is realized,and the operation speed and accuracy can be greatly increased. The experiment indicate that the measurement accuracy of RMS value is up to 2% ,and the measurement accuracy of flicker value is up to 2%.
作者 张克明
出处 《电子测量技术》 2013年第5期87-90,96,共5页 Electronic Measurement Technology
关键词 电压波动 闪变 现场可编程门阵列 ARM9 快速傅里叶变换 voltage fluctuatiom flieker FPGA ARM9 FFT
  • 相关文献

参考文献12

二级参考文献86

共引文献96

同被引文献52

  • 1陈祥训.实时跟踪电压闪变幅度的移动不变小波分析方法[J].中国电机工程学报,2004,24(10):1-7. 被引量:33
  • 2AMMAR M, JOOS G. Impact of distributed wind genera- tors reactive power behavior on flicker severity[ J]. IEEE Transactions on Energy Conversion, 2013, 28 ( 2 ) : 425 -433.
  • 3CHENG J Y, HSIEH C T, HUANG S J, et al. Applica- tion of modified Wigner distribution method to vohage flicker-generated signal studies[ J]. International Journal of Electrical Power & Energy Systems, 2013, 44 ( 1 ) : 275-281.
  • 4RUIZ J, GUTIERREZ J J, LAZKANO A, et al. A review of flicker severity assessment by the IEC flicker- meter[ J ]. IEEE Transactions on Instrumentation and Measurement, 2010, 59(8): 2037-2047.
  • 5HUANG S J, LU C W. Enhancement of digital equivalent voltage flicker measurement via continuous wavelet trans- form [ J ]. IEEE Transactions on Power Delivery, 2004, 19(2) : 663-670.
  • 6OLESKOVICZ M, COURY D V, FELHO O D, et al. Power quality analysis applying a hybrid methodology with wavelet transforms and neural networks [ J ]. International Journal of Electrical Power & Energy Systems, 2009, 31(5) : 206-212.
  • 7TSE N, CHAN J, LAU W H, et al. Hybrid wavelet and hilbert transform with frequency-shifting decomposition for power quality analysis [ J ]. IEEE Transactions on Instru- mentation and Measurement, 2012, 61 ( 12 ) : 3225 -3233.
  • 8AL-HASAWI W M, EL-NAGGAR K M. A genetic based algorithm for voltage flicker measurement [ J ]. Interna- tional Journal of Electrical Power & Energy Systems, 2004, 26 (8) : 593-596.
  • 9AL-KANDARI A M, SOLIMAN S A, ALAMMARI R A. Power quality analysis based on fuzzy estimation algo- rithm : Voltage flicker measurements [ J ]. International Journal of Electrical Power & Energy Systems, 2006, 28(10): 723-728.
  • 10FEILAT E A. Detection of voltage envelope using Prony analysis-Hilbert transform method [ J ]. IEEE Transac- tions on Power Delivery, 2006, 21(4): 2091-2093.

引证文献4

二级引证文献24

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部